Before you use this product

  • Please make sure you read the instruction manual carefully.
  • Following and respecting the instructions in your manual will prevent damage to your instrument and loss of your statutory rights arising from defects due to incorrect use.
  • We shall not be liable for any damage occurring as a result of non-following of these instructions. Likewise, we take no responsibility for any incorrect readings or for any consequences resulting from them.
  • Please pay particular attention to the safety notices!
  • Please keep this instruction manual safe for future reference.

Field of operation

  • Current temperature / MAX/MIN/HOLD / probe 75 mm / also for food checks (according to HACCP)

warning For your safety

  • The device should only be used as described in your instruction manual.
  • Keep this device and the battery out of reach of children.
  • Small parts can be swallowed by children (under three years old).
  • Batteries contain harmful acids and may be hazardous if swallowed. If a battery is swallowed, this can lead to serious internal burns and death within two hours. If you suspect a battery could have been swallowed or otherwise caught in the body, seek medical help immediately.
  • Batteries must not be thrown into a fire, shortcircuited, taken apart or recharged. Risk of explosion!
  • Low batteries should be changed as soon as possible to prevent damage caused by leaking.
  • Avoid contact with skin, eyes and mucous membranes when handling leaking batteries. In case of contact, immediately rinse the affected areas with water and consult a doctor.
  • Do not expose the device to extreme temperatures, vibrations or shocks. Protect it from moisture.
  • Only the probe is heat resistant up to 200°C.
  • Never hold the probe directly over fire.
  • Do not use the instrument in the oven or microwave.
  • Unauthorized repairs, modifications or changes to the product are prohibited.
  • Clean your instrument with a soft damp cloth. Do not use solvents or scouring agents.
  • Do not immerse the display element into water. Water can penetrate into the precision sensor and cause malfunction. Not suitable for dishwasher.
  • Be careful when handling the probe. When the device is not used, put the protective cap over the probe.
  • The product is not be used for medical purpose.

Getting started/Operation

  • Remove the protective cap from the probe.
  • Press the ON/OFF button, to turn on the device.
  • The display shows the currently measured temperature. The sensor is located in the point of the probe.
  • To measure the temperature, insert the probe at least 2,5 cm deep in the object.
  • The temperature unit can be changed from °C to °F by the °C/°F button.
  • Press the MODE button once in normal mode and the hold-function is activated (on the display appears HOLD).
  • Press the MODE button again and the maximum temperature is shown since the last reset (on the display appears MAX).
  • Press the MODE button again and the minimum temperature is shown since the last reset (on the display appears MIN).
  • Press the MODE button again to return to normal mode.
  • To clear the maximum and minimum memory, press and hold the MODE button for 3 seconds in the corresponding mode while MAX or MIN is displayed (indicated by ---). Press the MODE button again to return to normal mode.
  • Press and hold MODE button for 3 seconds in normal mode, to deactivate or activate the automatic off-function.
  • X appears or disappears on the display.
  • Change the battery when the functions of the device become weak.
  • Open the battery compartment and insert a new battery LR44 polarity as illustrated (+pole above).

Troubleshooting

Problems Solutions

No display

  • Ensure battery polarity is correct (+ pole above)
  • Change the battery
  • Switch on the instrument (ON)

Incorrect display

  • Check the position of the sensor
  • Change the battery

Specifications

Measuring range -40°C to +200°C
(-40°F to 392°F)
Operating temperature -20°C to +50°C
(-4°F to 122°F)
Precision ±0.8°C (±1.4°F)
from 0°C to +100°C
(32°F to 212°F),
±1.0°C (±1.8°F)
from -20°C to 0°C
(-4°F to 32°F)
otherwise ±1.5°C (±2.7°F)
Resolution 0.1°C (0.1°F)
Power consumption LR 44 button cell (included)
Auto switching-off function after 5 minutes
Dimensions 20 x 16 x 152 mm
Weight 13 g (instrument only)

This product fulfills the guidelines according to EN 13485.
Suitability: S, T (Storage, Transport)
Location: E
Accuracy class: 1
Measuring range: -40°C..+200°C
In accordance with EN 13485, this instrument is subject to regular inspections as per EN 13486 (recommendation: yearly)

TFA Dostmann GmbH & Co. KG
Zum Ottersberg 12, 97877 Wertheim, Germany
No part of this manual may be reproduced without written consent of TFA Dostmann. The technical data are correct at the time of going to print and may change without prior notice. The latest technical data and information about this product can be found in our homepage by simply entering the product number in the search box.
www.tfa-dostmann.de

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download TFA 30.1013 - Digital Probe Thermometer Manual

Advertisement

Need help?

Need help?

Do you have a question about the 30.1013 and is the answer not in the manual?

Questions and answers

Table of Contents