Presetting The Butterfly Valves - GEM R480 Victoria Operating Instructions Manual

Hide thumbs Also See for R480 Victoria:
Table of Contents

Advertisement

14.4 Presetting the butterfly valves

1. Move the butterfly disc to the closed position.
2. Determine the L1 and L2 dimensions and use them to cal-
culate the L dimension.
3. The butterfly disc must be turned out of the seal seat in
the closed position. (Anticlockwise)
4. Comply with the L dimension when setting.
5. If readjustment is necessary, open the butterfly disc and
adapt the presetting.
6. Repeat steps 1 to 4 until the L dimension has been
reached.
7. In the open position, the disc must be set to 90°, otherwise
the Kv value will be reduced.
DN
25
2.0
40
2.0
50
2.0
65
2.0
80
2.0
100
2.0
125
2.0
150
7.7
200
8.9
250
10.0
300
11.0
350
11.8
400
12.6
450
13.4
500
14.1
600
15.5
www.gemu-group.com
L [mm]
W [°]
9.1
5.7
4.6
3.5
2.9
2.3
1.8
3.0
2.6
2.3
2.1
1.9
1.8
1.7
1.6
1.5
39 / 46
14 Inspection and maintenance
GEMÜ R480 Victoria

Advertisement

Table of Contents
loading

Table of Contents