Replacement Of Spare Parts - GEM R480 Victoria Operating Instructions Manual

Hide thumbs Also See for R480 Victoria:
Table of Contents

Advertisement

15.4 Replacement of spare parts

▶ Assembly instructions for replacing the wearing parts are
included with every wearing parts kit.
15.4.1 Replacing the SVK wearing parts kit
15.4.1.1 Lug
9
9
10
11
12
1. Loosen and remove the hexagon head bolt 10 with pin.
2. Remove the support ring 7, O-ring 8 and bush 9.
3. Pull the shaft 6 out upwards.
4. Undo the threaded plug 3, remove the O-ring 4 and bush 2.
5. Pull the axis 5 out downwards.
6. Assemble the wearing parts kit in reverse order.
www.gemu-group.com
NOTICE
2
3
4
15.4.1.2 Wafer
10
7
8
7
11
6
1
12
1. Loosen and remove the hexagon head bolt 10 with pin.
5
2. Remove the support ring 7, O-ring 8 and bush 9.
3. Pull the shaft 6 out upwards.
4. Undo the threaded plug 3, remove the O-ring 4 and bush 2.
5. Pull the axis 5 out downwards.
6. Assemble the wearing parts kit in reverse order.
15.4.2 Replacing the SDS wearing parts kit
1. Disassemble the SVK wearing parts kit (see chapter "Re-
placing the SVK wearing parts kit").
2. Remove the butterfly disc 12.
3. Assemble the wearing parts kit in reverse order.
15.4.3 Replacing the SLN wearing parts kit
1. Disassemble the SVK wearing parts kit (see chapter "Re-
placing the SVK wearing parts kit").
2. Disassemble the SDS wearing parts kit (see chapter "Re-
placing SDS wearing parts kit").
3. Remove the liner 11.
4. Assemble the wearing parts kit in reverse order.
43 / 46
15 Spare parts
9
9
2
3
4
GEMÜ R480 Victoria
7
8
7
6
1
5

Advertisement

Table of Contents
loading

Table of Contents