This type of control is available only after purchasing and connecting an additional controlling module ST-65 which is
not included in the standard controller set.
If the controller is equipped with additional GSM module, it is necessary to activate it by selecting ON.
GSM Module is an optional device which, cooperating with the controller, enables the user remote control of the CH boiler
operation via a mobile phone. The user is sent an SMS each time an alarm occurs. Moreover, after sending a certain text
message, the user receives feedback on the current temperature of all the sensors. Remote change of the pre-set temperatures
is also possible after entering the authorisation code.
GSM module may operate independently of the CH boiler controller. It has two additional inputs with temperature sensors, one
contact input to be used in any configuration (detecting closing/opening of contacts) and one controlled output (e.g. a possibility
of connecting an additional contractor to control any electric circuit).
When any of the temperature sensors reaches the pre-set maximum or minimum temperature, the module automatically sends
an SMS with such information. A similar procedure is used in the case of opening or closing of the contact input, which may be
used as a simple means of property protection.
6.4
E
THERNET MODULE
FITTER'S
MENU
Before registering the module, it is necessary to create user's account on emodul.pl (if you do not have one).
Once the module has been connected properly, select Module ON.
Next, select Registration. The controller will generate a code.
ETHERNET
ON/OFF
MODULE
21
DHCP
IP address
DNS address
Gate address
DNS address
Version
Register