Montering; Allmänna Monteringsanvisningar; Dimensioner - schmersal RSS 36-D-ST5 Manual

Safety switch
Hide thumbs Also See for RSS 36-D-ST5:
Table of Contents

Advertisement

Available languages

Available languages

(1) This device may not cause harmful interference signals, and
(2) This device must be able to tolerate interference signals. These also include interference signals that could
cause the device to function improperly.
This device complies with the nerve stimulation limits (ISED SPR-002) when operated at a minimum distance of 100
mm. Changes or modifications not expressly approved by K.A. Schmersal GmbH & Co. KG could void the user's
authority to operate the equipment.
The licence-free transmitter/receiver contained in this device satisfies the requirements of the "Radio Standards
Specification" of the Innovation, Science and Economic Development Canada (ISED) authority that apply to licence-
free radio equipment. Operation is permissible under the following two conditions:
(1) The device must not create disturbances.
(2) The device must tolerate received radio frequency interference, even if this could impair its functionality.
This device complies with the nerve stimulation limits (ISED CNR-102) when operated at a minimum distance of 100
mm.
In the event of changes or modifications that have not been expressly approved by K.A. Schmersal GmbH & Co. KG,
the user's authorisation to use the device may become ineffective.
ANATEL-Hinweis
Este equipamento nao tem direito àprotecao contra interferência prejudicial e nao pode causar interferencia em
sistemas devidamente autorizados.
Para maiores informacores consultar: www.gov.br/anatel

4 montering

4.1 Allmänna monteringsanvisningar
Please observe the relevant requirements of the standards ISO 12100, ISO 14119 and ISO 14120.
2
Ensure the safety sensor and actuator is mounted on a flat surface. The component can be mounted in any position.
The universal mounting holes provide for a variable mounting by means of M4 screws. Mounting: a screw length of
25 mm is sufficient for sensor mounting and for side mounting of the actuators. 30 mm long screws are
recommended when the actuator is mounted upright and/or when the sealing discs are used. (Tightening torque
2,2...2,5 Nm). The labelled surfaces of the safety sensor and the actuator have to be opposite. The safety sensor
must only be used within the assured switching distances ≤ sao and ≥ sar.
To avoid any interference inherent to this kind of system and any reduction of the switching distances, please
observe the following guidelines:
The presence of metal chips in the vicinity of the sensor is liable to modify the switching distance.
Keep away from metal chips
Minimum distance 100 mm between two safety sensors as well as other systems with same frequency (125
kHz)
Säkerhetshandtaget skall på lämpligt sätt monteras på skyddsanordningen så att den inte går att lossa eller att flyttas
2
(t.ex. engångsskruvar, limma, borra upp skruvhuvuden, stifta).

4.2 Dimensioner

9-22

Advertisement

Table of Contents
loading

Table of Contents