schmersal AZM300 Operating Instructions Manual

schmersal AZM300 Operating Instructions Manual

Solenoid interlock

Advertisement

Operating instructions
Solenoid interlock
Operating instructions. . . . . . . . . . . .pages 1 to 12
EN
Original
Content
1
About this document
1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2.6 Safety classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3.2 Manual release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
3.4 Mounting with mounting plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
3.5 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
3.6 Actuator and accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .7
5
5.1 Magnet control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
5.2 Mode of operation of the safety outputs. . . . . . . . . . . . . . . . . . . . . .7
5.3 Actuator coding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
5.4 Adjustment of the latching force. . . . . . . . . . . . . . . . . . . . . . . . . . . .7
6
6.1 Diagnostic-LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
7
7.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
7.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
8
8.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
8.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
9
9.1 Wiring examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
1.
About this document

1.1 Function

This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety switchgear. The operating
instructions must be available in a legible condition and a complete
version in the vicinity of the device.

1.2 Target group: authorised qualified personnel

All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components.

1.3 Explanation of the symbols used

Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.

1.4 Appropriate use

The products described in these operating instructions are developed
to execute safety-related functions as part of an entire plant or machine.
It is the responsibility of the manufacturer of a machine or plant to
ensure the correct functionality of the entire machine or plant.
The safety switchgear must be exclusively used in accordance with
the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".

1.5 General safety instructions

The user must observe the safety instructions in this operating
instructions manual, the country specific installation standards as well
as all prevailing safety regulations and accident prevention rules.
EN
AZM300
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AZM300 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for schmersal AZM300

  • Page 1: Table Of Contents

    Operating instructions Solenoid interlock AZM300 Diagnostic function 6.1 Diagnostic-LEDs ........7 6.2 Solenoid interlock with conventional diagnostic output .
  • Page 2: Warning About Misuse

    ➄ Emergency release the line loss. Series-wiring of up to 31 AZM300 … SD components with Emergency exit serial diagnostics is possible. In devices with the serial diagnostics Emergency exit, distance 8.5 mm...
  • Page 3: Technical Data

    Limits (ISED SPR-002) for direct touch operations. Changes or - Peak current: < 0.35 A / 200 ms modifications not expressly approved by K.A. Schmersal GmbH & Required rated short-circuit current: 100 A Co. KG could void the user‘s authority to operate the equipment.
  • Page 4: Safety Classification

    Operating instructions Solenoid interlock AZM300 Mounting 2.6 Safety classification - of the interlocking function: Standards: ISO 13849-1, IEC 61508, IEC 62061 3.1 General mounting instructions Control Category: Please observe the relevant requirements of the standards PFH: 5.2 x 10 ISO 12100, ISO 14119 and ISO 14120.
  • Page 5: Manual Release

    For doors, which close flush with the door frame, the optional mounting has been returned to its original position late MP-AZ/AZM300-1 can be used. Caution: do not turn beyond the end stop! After being put into operation, the manual release must be sealed by means of the seal, which is included in delivery.
  • Page 6: Dimensions

    Operating instructions Solenoid interlock AZM300 3.5 Dimensions 3.6 Actuator and accessories All measurements in mm. Actuator AZ/AZM300-B1 (not included in delivery) Ø34 23. 4 Ø5 16. 4 Ø6. 7 Mounting plate MP-AZ/AZM300-1 (available as accessory) 87. 5 18. 5 17. 5 AZM300...-T/-T8 and -N...
  • Page 7: Electrical Connection

    5.1 Magnet control Diagnostic function In the power to unlock version of the AZM300, the solenoid interlock is unlocked when the IN signal (= 24V) is set. In the power to lock version of the AZM300, the solenoid interlock is locked when the IN 6.1 Diagnostic-LEDs...
  • Page 8 Input signal magnet control Any error that does not immediately affect the safe functionality of the AZM300 solenoid interlock (e.g. excess ambient temperature, safety output to external potential, short circuit) will lead to a delayed shut- down (refer to table 2).
  • Page 9: Solenoid Interlock With Serial Diagnostic Function Sd

    The necessary software for the integration of the SD-Gateway is individual components. available for download at products.schmersal.com. Accessories for the series-wiring The response data and the diagnostic data are automatically and...
  • Page 10: Set-Up And Maintenance

    Wiring example 1: Series-wiring of the AZM300 with conventional diagnostic output The voltage is supplied at both safety inputs of the terminal safety component of the chain (considered from the safety-monitoring module).
  • Page 11: Wiring Configuration And Connector Accessories

    Solenoid interlock AZM300 Wiring example 2: Series-wiring of the AZM300 with serial diagnostic function The safety outputs of the first safety component are wired to the safety-monitoring module. The serial Diagnostic Gateway is connected to the serial diagnostic input of the first safety component.
  • Page 12: Eu Declaration Of Conformity

    Solenoid interlock AZM300 10. EU Declaration of conformity EU Declaration of conformity Original K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives.

Table of Contents