With the combination of "old sensor - new actuator (V2)" there may be limitations in availability owing to the reduced s
F
(8 mm). This change has no affect on the performance level.
The side allows for a maximum height misalignment (X) of sensor and actuator of ± 8 mm (e.g. mounting tolerance
or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm.
Latching versions X ± 5 mm, Y ± 3 mm.
F
The latching force will be reduced by misalignment.
Actuating curves
The actuating curves represent the typical switching distance of the safety sensor during the approach of the
actuator subject to the actuating direction
Transverse misalignment
 
Preferred actuation directions: from front or from side
F

4.5 Adjustment

The continuous signal of the yellow LED signals the actuator detection; the flashing of the yellow LED signals that
the safety sensor is actuated in the hysteresis area.
Recommended Adjustment
F
Align the safety sensor and actuator at a distance of 0.5 x s
The correct functionality of both safety channels must be checked by means of the connected safety-monitoring
module.