Battery Charging - Viper AS5160-US User Manual

Table of Contents

Advertisement

Available languages

Available languages

USER MANUAL

BATTERY CHARGING

NOTE
Charge the batteries when the yellow (F,
Figure 14) or red warning light (G) turns
on, or when finishing cleaning.
CAUTION!
Keeping the batteries charged make their
life last longer.
CAUTION!
When the batteries are discharged, charge
them as soon as possible, as that condition
makes their life shorter. Check for battery
charge at least once a week.
WARNING!
WET battery charging produces highly
explosive hydrogen gas. Charge the
batteries in well-ventilated areas and
away from naked flames. Do not smoke
while charging the batteries. Keep the
tank open while charging the batteries.
WARNING!
Pay careful attention when charging the
batteries as there may be battery fluid
leakages. The battery fluid is corrosive. If
it comes in contact with skin or eyes, rinse
thoroughly with water and consult a
physician.
Preliminary procedures
1.
Open the cover (A, Figure14) and check that the recovery water tank (B) is empty, otherwise empty it with the
drain hose (C).
2.
Drive the machine on a level floor.
3.
Turn the ignition key (H) to "0".
4.
Carefully lift the tank (B).
5.
For WET batteries only:
Check the level of electrolyte inside the batteries (D); if necessary, top up through the caps (E).
Leave all the battery caps (E) open for next charging.
If necessary, clean the upper surface of the batteries (D).
6.
Charge the batteries according to the following procedure.
C
E
D
19
ENGLISH
H
G F
D
Figure 14
B
A

Advertisement

Table of Contents
loading

This manual is also suitable for:

As5160t-us5000040150000406As5160As5160t

Table of Contents