Download Print this page

Advertisement

Quick Links

DS-LEDUPS Series
*Actual configuration may vary
ENG Installation video for reference only.
Read and follow instruction manual for full installation.
1
2020-03-23 #:146-9048-5
(2020-11-09)

Advertisement

loading

Summary of Contents for peerless-AV DS-LEDUPS Series

  • Page 1 DS-LEDUPS Series *Actual configuration may vary ENG Installation video for reference only. Read and follow instruction manual for full installation. 2020-03-23 #:146-9048-5 (2020-11-09)
  • Page 2 WARNING ENG - This product is designed to be installed on plywood walls. Hardware is included for plywood installation. This product is designed to be installed on flat, unobstructed, vertical walls. Do not install on curved or angled walls. Before installing make sure the supporting surface will support the combined load of the equipment and hardware.
  • Page 3: Parts List

    Parts (Before beginning, make sure you have all parts shown below). Parts List left column right column inside column vertical spacer Description A left column B right column C inside column D top horizontal asy E bottom horizontal asy F top left horizontal asy G top right horizontal asy H bottom left horizontal asy bottom right horizontal asy...
  • Page 4 top left top right horizontal asy horizontal asy bottom left bottom right horizontal asy horizontal asy 2020-03-23 #:146-9048-5 (2020-11-09)
  • Page 5 Optional: If connecting two top horizontal extrusions, first remove inner hook-on brackets. Remove and save hardware. Use extrusion connectors to connect top horizontal 2.5mm extrusions. L (4) O (8) 2020-03-23 #:146-9048-5 (2020-11-09)
  • Page 6 Replace one hook-on bracket in between connected extrusions. Use saved hardware. Optional: If connecting two bottom horizontal extrusions, first remove inner hook-on brackets Remove and save hardware. 2020-03-23 #:146-9048-5 (2020-11-09)
  • Page 7 Use extrusion connectors to connect bottom 2.5mm horizontal extrusions. L (3) O (6) Replace one hook-on bracket in between connected extrusions. Use saved hardware. 2020-03-23 #:146-9048-5 (2020-11-09)
  • Page 8 WARNING ENG - When installing Peerless wall mounts on a wood stud wall covered with plywood, verify that the wood studs are a minimum of 2" x 4" nominal size and plywood is a minimum Grade BC, 1/2" (13 mm) thick. Plywood may be covered by gypsum board (drywall) up to 5/8"...
  • Page 9 1.25" (32mm) minimum for mounting clearance Use a laser level to keep mounting holes level. 2.75" (70mm) display tile 2020-03-23 #:146-9048-5 (2020-11-09)
  • Page 10 Level top horizontal extrusion and mark mounting holes on plywood (must be minimum Grade BC, 1/2" (13mm) thick.) 2020-03-23 #:146-9048-5 (2020-11-09)
  • Page 11 1.75" (44mm) 5/32" 5/32" (4mm) (4mm) Drill mounting holes into supporting surface (1.75" (44mm) minimum depth required). Level extrusion. Install using wood screws provided. 3/8" (10mm) Maximum 80 in. • lb (9 N.M.). 2020-03-23 #:146-9048-5 (2020-11-09)
  • Page 12 Edges must be flush. Secure vertical spacers to the wall flush with the horizontal extrusion. 3/8" (10mm) 2020-03-23 #:146-9048-5 (2020-11-09)
  • Page 13 Use third vertical spacer to align bottom horizontal extrusion flush with vertical spacer, then mark mounting holes on plywood (must be minimum Grade BC, 1/2" (13mm) thick.) Edges must be flush. 2020-03-23 #:146-9048-5 (2020-11-09)
  • Page 14 1.75" (44mm) 5/32" 5/32" (4mm) (4mm) Drill mounting holes into supporting surface (1.75" (44mm) minimum depth required). Use third vertical spacer to align bottom horizontal extrusion flush with vertical spacer, then install using wood screws 3/8" provided. (10mm) Maximum 80 in. • lb (9 N.M.). 2020-03-23 #:146-9048-5 (2020-11-09)
  • Page 15 3-10 Remove vertical spacers. 3/8" (10mm) 2020-03-23 #:146-9048-5 (2020-11-09)
  • Page 16 Hook on and secure outer vertical columns. "L" and "R" markings designate left and right Tighten hardware. column. 2020-03-23 #:146-9048-5 (2020-11-09)
  • Page 17 Hook on and secure all inside vertical columns. Tighten hardware. 2020-03-23 #:146-9048-5 (2020-11-09)
  • Page 18 Loosen hardware on vertical columns. 2020-03-23 #:146-9048-5 (2020-11-09)
  • Page 19 Plumb and level outer columns, then tighten hardware. Tighten hardware on four corner wall plates. Tighten. Tighten. 2020-03-23 #:146-9048-5 (2020-11-09)
  • Page 20 Tie a string between top slots on outer columns in order to level the depth of each vertical column. Loosen, adjust, tighten. Optional leveling for bowed walls Loosen. Insert. Tighten. 2020-03-23 #:146-9048-5 (2020-11-09)
  • Page 21 Tie a string between bottom slots on outer columns in order to level the depth of each vertical column. Loosen, adjust, tighten. Optional leveling for bowed walls Loosen. Insert. Tighten. 2020-03-23 #:146-9048-5 (2020-11-09)
  • Page 22 Tighten or loosen to adjust height. With the string still attached, level the height of each column. 2020-03-23 #:146-9048-5 (2020-11-09)
  • Page 23 Adjust inner columns to fit horizontal spacers. Tighen column hardware after spacing. Start from the left column. 2020-03-23 #:146-9048-5 (2020-11-09)
  • Page 24 Continue adjusting inner columns to fit horizontal spacers until all are level. Tighen column hardware after spacing. 2020-03-23 #:146-9048-5 (2020-11-09)
  • Page 25 Remove all spacers. 2020-03-23 #:146-9048-5 (2020-11-09)
  • Page 26 Optional: For shallow depth installations, flip wall bracket orientation as shown. 2.60" 2.25" (66mm) (57mm) 3.05" 2.65" (77mm) (67mm) 2020-03-23 #:146-9048-5 (2020-11-09)
  • Page 27 Level L brackets and mark mounting holes on plywood (must be minimum Grade BC, 1/2" (13mm) thick.) 2020-03-23 #:146-9048-5 (2020-11-09)
  • Page 28 1.75" (44mm) 5/32" 5/32" (4mm) (4mm) Drill mounting holes into supporting surface (1.75" (44mm) minimum depth required). Level L brackets. Install using wood screws provided. 3/8" (10mm) Maximum 80 in. • lb (9 N.M.). 2020-03-23 #:146-9048-5 (2020-11-09)
  • Page 29 Tie a string between center slots on outer column in order to level the depth of each vertical column. 2020-03-23 #:146-9048-5 (2020-11-09)
  • Page 30 Adjust depth, then remove string. Loosen, adjust, tighten. 2020-03-23 #:146-9048-5 (2020-11-09)
  • Page 31 This page intentionally left blank. 2020-03-23 #:146-9048-5 (2020-11-09)
  • Page 32 ENG Attach display and run cables one at a time starting from the bottom left. 2020-03-23 #:146-9048-5 (2020-11-09)
  • Page 33 2020-03-23 #:146-9048-5 (2020-11-09)
  • Page 34 ENG To remove, start from the top right. 2020-03-23 #:146-9048-5 (2020-11-09)
  • Page 35 This page intentionally left blank. 2020-03-23 #:146-9048-5 (2020-11-09)
  • Page 36 Garantia TÜR Garanti̇ Garanzia Záruka www.peerless-av.com/warranty Peerless-AV Peerless-AV Europe Peerless-AV América Latina 2300 White Oak Circle Unit 3 Watford Interchange, Av. de las Industrias 413 Aurora, IL 60502 Colonial Way, Watford, Herts, Parque Industrial Escobedo Email: tech@peerlessmounts.com WD24 4WP, United Kingdom General Escobedo N.L., México 66062...