Restarting the Scalar 10K

Caution
Warning

Using the Remote Management Unit

3-10
System Description
Use the following procedure to restart the Scalar 10K.
With the RMU installed, power up must be delayed by one
minute after a power down condition to allow the RMU to
properly reset.
Look into the aisle to make sure there are no obstructions or
personnel present prior to applying library power.
Movements of mechanical components in the library can
cause serious injury.
Step 1
If applicable, correct the situation that required the
Scalar 10K shutdown.
Step 2
Refer to Starting the Scalar 10K on page 4-7 for
instructions on the Scalar 10K start procedure.
The RMU is a component in the library that provides remote
access to the library by means of a Web browser. All functions
listed here are available without the need of a dedicated
server (or separate software).
The RMU performs the following functions:
Provides remote operation of all library operator panel
functions by means of a Web browser.
Allows you to check the status of the system, firmware
levels, and other useful information.
Updates RMU firmware.
Supports Simple Network Management Protocol (SNMP)
version 2.0 and acts as an SNMP-server, generating
SNMP traps and responding to SNMP requests.
Supports ADIC Library Management Information Base
(MIB) version 2.0.
Acquires Tape Alert 2.1 information from the library and
sends that information to an SNMP manager.
Detects a power loss and generates an SNMP trap for
notification.
Enables the retrieval of library logs, and drive and RMU
diagnostic files.