4-142 Menus and Commands

Step Dialog

Path: Main Menu Service Diags Tower Step
Use the Step Dialog to move the tower through each position.
See Figure 4-216.
This test should be
used by trained
personnel ONLY!
Continue: N <
Figure 4-216
Home Dialog
Parameters
Continue
If you are in SERVICE mode and Y is selected for the
Continue, the following display appears and the tower is
ready to position. See Figure 4-217.
If you are not in SERVICE mode and Y is selected for
Continue, the WRONG TOWER MODE display
appears, select Accept to change to SERVICE mode.
See Figure 4-218.
Position Tower
Tower:
01 LTO
Column:UNKNOWN <
Amount: 01
Figure 4-217
Position Tower
Parameters
Tower
Column
Amount
Description
Y to continue the test
N to cancel the test
Description
Tower to be moved
(01–14, 8mm, DLT, LTO,
HALF)
Column number
01A–12L for DLT, LTO, HALF
01A–16P for 8mm
The step width depending on
the media type
6-00058-05 Rev A