  • Page 1 Operating instructions aroSTOR VWL BM 200/5 VWL BM 270/5 KOsq Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-42859 Remscheid Tel. +492191 18 0 Fax +492191 18 2810 info@vaillant.de www.vaillant.de...
  • Page 2: Table Of Contents

    Contents Contents Type designation and serial number........... 9 Safety ..........4 Information on the data plate ..9 Action-related warnings ....4 CE marking ........10 Intended use ........4 Operation........10 Danger caused by improper Operating concept ....... 10 operation........
  • Page 3 Contents Appendix ..........16 Troubleshooting ......16 Optimising energy consumption ......17 Using a low tariff and a control cable connection......17 Using a low tariff without a control cable connection ....18 Operating with a fixed electricity tariff..........19 End user level –...
  • Page 4: Safety

    1 Safety 1 Safety Intended use includes the fol- lowing: 1.1 Action-related warnings – observance of the operating Classification of action-re- instructions included for the lated warnings product and any other install- The action-related warnings ation components are classified in accordance –...
  • Page 5: Danger Caused By Improper Operation

    Safety 1 ▶ Leave the building immedi- 1.3 Danger caused by improper operation ately and ensure that others do not enter the building. Improper operation may present a danger to you and others, and 1.5 Risk of death due to cause material damage.
  • Page 6: Risk Of Being Scalded By Hot Drinking Water

    1 Safety 1.7 Risk of being scalded by 1.9 Risk of injury and hot drinking water material damage due to maintenance and repairs There is a risk of scalding at carried out incorrectly or the hot water draw-off points not carried out at all if the hot water temperatures ▶...
  • Page 7: Frost Damage Due To Insufficient Room Temperature

    Safety 1 ▶ Consult your installer before disposed of in accordance with undertaking the work in ques- regulations. tion. ▶ Ensure that only officially cer- tified competent persons with 1.12 Frost damage due to appropriate protective equip- insufficient room ment carry out maintenance temperature work on the refrigerant circuit If the room temperature is set...
  • Page 8: Notes On The Documentation

    2 Notes on the documentation 2 Notes on the 3.1 Product design documentation Validity: aroSTOR VWL BM 200/5, aroSTOR VWL BM 270/5 2.1 Observing other applicable documents ▶ You must observe all operating instruc- tions enclosed with the system compon- ents.
  • Page 9: Displayed Symbols

    Product description 3 3.3 Displayed symbols Information on the Meaning data plate Sym- Meaning Coefficient of per- formance – heating Compressor in operation 230 V (single-phase) Voltage and fre- ~ 50 Hz quency of the Fan in operation product's power Defrosting function active supply P max...
  • Page 10: Ce Marking

    4 Operation 4.2 Switching on the product Information on the Meaning data plate The cylinder con- tains a combustible product See instructions 3.6 CE marking 1. Before starting up the product, ensure   that the plugs (1) have been removed The CE marking shows that the products from the condensate discharge con- comply with the basic requirements of the...
  • Page 11: Setting The Language

    Operation 4 ▶ heating is permitted by the electricity Press the button to set the time. ▶ tariff. Press the rotary knob to confirm. ◁ ▶ When the heat pump is running, Turn the rotary knob to set the day. ▶...
  • Page 12: Additional Domestic Hot Water Temperature Setting When A Photovoltaic Installation Is Connected

    4 Operation 4.7 Additional domestic hot water 4.8 Programming operating times temperature setting when You can optimise the product's energy a photovoltaic installation is consumption (kWh) by programming the connected operating hours. Consider the following points when creating such a programme: Note –...
  • Page 13: Setting The Holiday Mode

    Operation 4 ◁ The end of the operating time is The mode ends automatically once automatically displayed as 24:00. the set number of days has expired. ▶ Throughout the holiday, the display shows Press the rotary knob. ▶ HOLI.RETUR. (return from holiday) and Press the menu button to return to the the number of days remaining.
  • Page 14: Setting Limp Home Mode

    5 Troubleshooting 4.11 Setting limp home mode information about the anti-legionella func- tion. This mode enables a limp home mode for cases where use of the heat pump is pre- 4.13 Frost protection function vented (air pipes not yet connected, dust- Note intensive work in the product's vicinity…).
  • Page 15: Checking The Condensate Discharge Pipe And Tundish

    Për të dhënat e kontaktit për shërbimin tonë të klientit, mund të shkruani në adresën që gjeni në faqen e pasme ose në 8 Recycling and disposal faqen e internetit www.vaillant.com. ▶ The competent person who installed your product is responsible for the dis- posal of the packaging.
  • Page 16: Appendix

    Appendix Appendix A Troubleshooting Fault Cause Solution The product no longer The power supply is interrupted. Ensure that there has works. not been a power cut and that the product is correctly connected to the power supply. When the power supply is re- established, the product automatically starts up.
  • Page 17: B Optimising Energy Consumption

    Appendix Fault Cause Solution The condensate does not The condensate discharge hose is Check the condensate drain off (water under- partly or completely blocked discharge hose. neath the product). There is a kink in the condensate discharge hose and this is forming a trough.
  • Page 18: Using A Low Tariff Without A Control Cable Connection

    Appendix – LT: Heat pump – LT: Heat pump Overview of the operating Heat pump and mode and immersion and immersion immersion heater heater (where heater (where heat the domestic applicable) heat applicable) heat hot water cylinder the domestic hot the domestic hot without any time re- water cylinder...
  • Page 19: Operating With A Fixed Electricity Tariff

    Appendix – LT: Only the heat – LT: Heat pump – LT + HT up to Overview of the operating mode pump heats the and immersion 12:00: Heat domestic hot heater heat the pump and immer- water cylinder domestic hot sion heater heat water cylinder the domestic hot...
  • Page 20: C End User Level - Overview

    *) Exception: The air temperature lies outside the range between -7 °C and +35 °C. In this case, operation of the back-up heater is permitted. C End user level – overview Validity: Vaillant Setting level Values Unit...
  • Page 21 Appendix Setting level Values Unit Increment, select, explana- Factory set- tion ting Min. Max. BA CK UP ELEC.BACKP ELEC.BACKP LAN GUAGE → LAN GUAGE 16 available languages INST.MENU → 0020290841_00 aroSTOR Operating instructions...
  • Page 24 0020290841_00 0020290841_00 23.06.2019 Supplier Vaillant d.o.o. Heinzelova 60 10000 Zagreb Tel. 01 6188 670 Tel. 01 6188 671 Tel. 01 6064 380 Tehnički odjel 01 6188 673 Fax 01 6188 669 info@vaillant.hr www.vaillant.hr © These instructions, or parts thereof, are protected by copyright and may be reproduced or distributed only with the manufacturer's written consent.