3.1.3 Normal Operation — Fault / Clean / Media LEDs
Indicator Activity
The Fault, Clean, and Media LEDs work together to display the status of the tape drive.
Table 3-3. Normal Operation — Fault / Clean / Media LEDs Indicator Activity
Fault
Key
81-81275-01 REV A02
Clean
Media
Off
On
Blinking–slow (approximately once per second)
Blinking–medium (approximately twice per second)
Blinking–fast (approximately three times per second)
Indicates that the status of this LED does not depend on the specific tape drive condition. This
means that certain tape drive conditions may result in a combination of two or more of the
LED states in the chart.
For example, if you need to clean the tape drive while a DLT1 tape is loaded, both the Clean
LED and Media LED are on steadily. If an internal write/read diagnostic fails due to a
permanent write error, both the Fault LED and Clean LED blink slowly.
September 2004
Description
Unsupported format, unsupported data cartridge type, or
damaged data cartridge
A DLT1 (DLT VS 80) formatted DLTtape™ IV data
cartridge is loaded.
Calibration error or permanent write/read error
Cleaning required—250 tape motion hours exceeded since
last cleaning
Cleaning in process
User invoked write/read diagnostic failed
Servo or mechanical error
Internal firmware error