Wel-200 Programming - Max 1200FS pro Installation Manual

Table of Contents

Advertisement

CONNECTING RECEIVER (WEL-200R) TO TRANSMITTER (WEL-200T)
Connecting is a two step process. First, on the receiver, press and hold the channel assignment switch until the green status LED
begins rapidly flashing, then release; this will clear any existing assignment for that particular channel. Hold down the
connection switch on the transmitter. If it is not currently connected to a receiver, it will begin flashing rapidly until successfully
connecting. Detailed instructions are given below.
1
2
3
4
5
If there are no existing connections, the receiver's status LED will blink rapidly
while it is finding a clean operating frequency (this can last a few seconds)
After initialization, the system status LED will flash on/off once every 2 seconds
Set
channel to the desired OPEN/CLOSE direction function using the MODE dip switch
Install 2 AA Lithium batteries in the WEL-200T (transmitter)
The green LED on the transmitter will quickly flash 2x every two seconds
Install a properly terminated edge to the transmitter (8.2k or 10k termination)
On the receiver, hold down the desired channel assignment switch until all four channel
LEDs activate and the system status LED begins flashing rapidly, then release
the switch.
On the transmitter, hold down the connection switch (next to the terminal block)
The LED on the transmitter will begin flashing rapidly after ~4 seconds
Upon successful connection, the LED will flash once every two seconds If
the transmitter fails to connect, it will return to its initial state, with the
LED flashing twice every two seconds. If this occurs, repeat step
Testing
Without activating the edge, observe the channel status LED, it should be OFF.
When the edge is activated, the receiver channel status LED will turn on and the
corresponding OPEN/CLOSE direction output will activate. The
transmitter status LED will blink once every second when the edge is activated.
If the channel does not exhibit this behavior, double check the edge
wiring/termination and transmitter batteries.
Testing
Power down receiver. Hold channels 1 and 4 down simultaneously while
powering receiver back up.
STEPS
TESTING
FACTORY RESET