Wiring Opening Device Options; Learn Unlearned Sensor Inputs - Max 1200FS pro Installation Manual

Table of Contents

Advertisement

11

wiring opening device options

250 mA Max.
12 VDC
OR
12V Power
24 VDC
Radio
Power
Stand-Alone Keypad
less than 200 mA
Radio Receivers
Emergency Open Device
Emergency OPEN
(Overrides gate
disable switch)
12

LEARN unlearned sensor inputs

Indicated Inputs MUST be "LEARNED" before gate operator will MONITOR those sensors.
1. Sensors that have been wired to indicated inputs MUST be "LEARNED" BEFORE they will be MONITORED.
2. Press and HOLD the STOP button & then the OPEN button together until beeping is heard, learn mode begins.
DO NOT press the OPEN button before the STOP button or learn mode will NOT begin (no beeping).
NOTE: Sensors wired to the
They are
"AUTOMATICALLY
3. LEDs WILL turn ON for each detected "LEARNED" sensor that has been wired to the inputs.
If a sensor's LED is NOT on, that sensor has a problem and it MUST be corrected before continuing.
Possible problems:
Photocells are out of alignment
Photocells are wired wrong - N.C. or N.O. depending on which photocells are used
Sensor is bad
When all LEDs are ON that should be ON, proceed to next step.
4. Press STOP button again within 5 min. to learn sensors and end learn mode, beeping stops.
Wired "Learned" Inputs will now be MONITORED.
NOTE: If STOP button is not pressed within 5 min., learn mode terminates.
If no "LEARNED" sensors are detected then factory default setting is restored (Inputs will NOT be Monitored).
BATTERY
BATTERY VOLTAGE
INPUT
E
1/2
F
ERROR
BATTERY
BATTERY
INPUT
BACKUP MODE
BATTERY
LEAVE
OPEN
IN USE
OPEN
1 TIME
REPLACE
LEAVE
BATTERY
BATTERY
POWER /
CLOSED
TEST
POWER
SOLAR IN
ERD SENSITIVITY
14
12
14
12
16
16
MIN
MIN
ERD
1
9
1
MAX
MOTOR
MAX
MODULE
SENSE
OVER
SENSE
3
7
3
PORT
LOAD
OPENING
CLOSING
OBD PORT
RESET /
BLACK BOX
MATRIX III
MANUAL
RELEASE
OFF
SWING / SLIDE
1
2
ALARM
3
4
5
MOTION CONTROL
PROGRAMMING
ID PLUG
6
ERROR
1
2
3
ID
4
PLUG
5
6
7
OPEN
STOP
PROGRAM
8
9
10
OFF
QUICK
EXIT PWR
OPEN
SOLAR MODE
CLOSE
LEFT
EXIT
LOOP
OFF
ON
GND
OFF
ON
CENTER
LOOP
LOOP PWR
GATE SPEED
SAFETY
LOOP
OPERATOR
MIN
MIN
FAULTS
MAX
MAX
PRIMARY
SECONDARY
24VDC OUTPUT
GND
OPENING
12VDC OUTPUT
GND
LINK
OK
PRIMARY/
SECONDARY
LINK
Dry Contact
(N.O.)
Telephone
(N.O.)
Dry Contact (N.O.)
PHOTO CLS NC
input and
OPEN ONLY NC
MONITORED".
MATRIX III
MOTOR
INPUTS
MOTOR
POSITION
INPUTS
CLOSE
TIMER
SLIDER
ERD
LIMIT
9
MOTOR
OVER
7
SWING
LOAD
MIN
MAX
OFF
LIMIT
ON/OFF
BATTERY
JOG
GATE OPEN
COM
GATE CLOSED
GND
LEFT
RIGHT
NO
CLOSE
MAG
LOCK
COM
NC
MAGLOCK
OPEN
RIGHT
DELAY
OPEN ONLY
NC
PHOTO CLS
NC
GATE
OFF
2.5 sec
OPEN/CLS
NC
External Alarm
1.5 sec
12VDC OUT
GND
Reset Button
OPEN ONLY
10K
UL
ENTRAP
CLS ONLY
10K
CLOSING
OPEN/CLS
10K
12VDC OUT
GND
Com
Normal Opening Devices
Key Switch
Card Reader
Separate power
for Devices if required.
Entry
input do NOT need to be "Learned".
UL 325 2018 Standard - MAX 1200 FS PRO/1700 FS PRO Matrix III Install Version 2c
12
Maglock
Bi-parting gates using locks:
-
+
Primary gate opens FIRST. Install
-
lock accordingly to account for this.
+
MAGLOCK LED (Monitors Maglock):
ON - Locked
Flashing - Problem with Maglock Power.
You MUST select a time delay when using
a maglock. Maglock power disengages 1.5
sec or 2 sec before gate starts opening.
Dual Gate Operators using Maglock:
S
E S
P R
Primary gate opens FIRST. Install maglock
T
S E
R E
accordingly to account for this.
t o
Stop
(N.O.)
Manual Release
Keypad
Safety Open Device
(N.O.)
Dry Contact
MOTION CONTROL
OPEN STOP
CLOSE
OPEN ONLY
NC
Factory Learned Input
PHOTO CLS
NC
Factory Learned Input
Unlearned Input
OPEN/CLS
NC
12VDC OUT
GND
O
O
O
O
O
OPEN ONLY
10K
Unlearned Input
C
C
CLS ONLY
10K
Unlearned Input
Unlearned Input
OPEN/CLS
O
O
10K
12VDC OUT
GND
MOTION CONTROL
STOP
OPEN
CLOSE
Gnd
-
+
NO
Solenoid Lock
OFF - Unlocked
MAGLOCK DELAY:
Key will manually
release slide gate
Safety Device
MAX OPEN Switch
(Overrides gate
disable switch)

Advertisement

Table of Contents
loading

This manual is also suitable for:

1700fs pro

Table of Contents