Table Column Set E HD ESD ― Installation guide Contents Symbols, safety ..........................................3 General safety information ......................................3 Correct use ..........................................5 Improper use ..........................................5 Personnel qualifications ......................................6 Product description ........................................7 Operating data ..........................................8 Setting up the height-adjustable table columns – environmental considerations ..................9 Levelling ............................................9 Electrical connections for height-adjustable tables ............................
Table Column Set E HD ESD ― Installation guide Symbols, safety Important information Observe directions for disposal Observe packaging instructions Caution: Risk of cable break, failure to observe this safety instruction can result in serious injury or death Caution: Risk of crushing, failure to observe this safety instruction can result in serious injury or death Maintenance Note! Failure to observe this safety instruction can result in material damage Warning! Failure to observe this safety instruction can result in material damage, serious injury or death...
Page 4
Table Column Set E HD ESD ― Installation guide ▪ Use only item products that are in perfect working order. ▪ Failure to use original spare parts will invalidate the product warranty! ▪ Check the product for obvious defects. ▪ Use the product only within the performance range described in the technical data.
Table Column Set E HD ESD ― Installation guide Correct use The Table Column Set is a partly completed machine as defined in the Machinery Directive (2006/42/EC). The electrically height-adjustable Table Column Set HD ESD must be used only in accordance with the technical data and safety requirements set out in this document.
Table Column Set E HD ESD ― Installation guide Take note of working areas where separate guidelines apply, particularly with regard to equipment and machinery: ▪ In the event of use at funfairs and amusement parks. ▪ In food preparation or where special hygiene stipulations apply. ▪...
Table Column Set E HD ESD ― Installation guide Product description The item Table Column Set HD ESD is the basis for customised, electrically height-adjustable work benches. The stable table columns support varying working positions with a maximum travel distance of 400 mm. Three different working heights can be saved to introduce ergonomics into day-to-day work by ensuring tables can be adapted to suit different people working different shifts.
Table Column Set E HD ESD ― Installation guide Operating data Max. load, Table Column Set 2 E HD ESD 6000 N Max. load, Table Column Set 4 E HD ESD 10000 N Max. speed 9 mm/s Noise emissions < 60 dB(A) Travel range of Table Column Set E HD ESD 400 mm Minimum installation height...
Table Column Set E HD ESD ― Installation guide Appropriate components can be selected and installed to ensure the Table Column Set is suitable for use in areas where electrostatic charges pose hazards. We recommend you consult your item representative. stat.: 1200 Nm stat.: 450 Nm...
Table Column Set E HD ESD ― Installation guide ▪ The distance between the columns should be limited in line with the anticipated loads. Observe the permissible static and dynamic bending moments on the table columns. ▪ The table columns must not be fastened to the floor (avoid force guidance). ▪...
Page 11
Table Column Set E HD ESD ― Installation guide Motor + Pulse 2 5V Hall Sensor GND Hall Sensor Pulse 1 Motor - Control set 4E HD 0.0.699.91 Control unit 4E HD 0.0.699.94 Control set 2E HD 0.0.699.90 Control unit 2E HD 0.0.699.93 Observe the following points when installing and operating the control system: ▪...
▪ Stop using the device immediately if it begins to emit smoke or an odour, operates in an unexpected way, makes unusual noises or shows visible signs of damage. Disconnect the system from the mains by removing the plug. ▪ The control system may only be used with item table columns. Manual controls...
Table Column Set E HD ESD ― Installation guide Start-up Ensure that connecting cables and electrical lines are not bent, pulled or subjected to mechanical loads. Lines, cables, etc. must not be laid in the foot area of the table columns in particular (safety area of approx. 100 mm around the table column feet).
Table Column Set E HD ESD ― Installation guide The height-adjustable construction can be damaged if it comes into contact with obstacles, and its service life may be short- ened. Keep the travel area beneath the table top and in the safety area around the table column feet clear. Table design: Table tops or attachments must be rigidly connected to the drive system.
Table Column Set E HD ESD ― Installation guide Caution: As far as possible, the table columns must not be under load when performing a RESET and any superstructure must be removed. Operation Display DOWN Manually adjusting the table column height (UP/DOWN) Use the “DOWN”...
Table Column Set E HD ESD ― Installation guide Safety range A certain section of the table column (a few centimetres before the lower stop position) is referred to as the safety range. When table columns reach this point, they stop. When the “DOWN” button is pressed again, they continue moving down, but at a reduced speed.
Table Column Set E HD ESD ― Installation guide To move the system to the saved position, hold down one of the three buttons – M1, M2 or M3 – until the corresponding position is reached. Setting the upper and lower travel limits The travel distance can be electronically limited to prevent collision with any potential obstacles in the travel range.
Table Column Set E HD ESD ― Installation guide Setting the display height ▪ To enter setting mode, press and hold down the “M1”, “M2” and “UP” buttons at the same time for 4 seconds. ▪ The display shows S01, with the S flashing. ▪...
Table Column Set E HD ESD ― Installation guide Error messages Cause Solution E 60 Motor power supply voltage below the Insert the power cord permissible minimum E 61 Total power has exceeded the pro- grammed limit value E 63 Inconsistent or damaged motor control parameters identified E 64 Tilt sensor has been triggered (exces-...
Page 20
Wired remote control faulty Replace wired remote control Drive only running downwards System overload Reduce the weight on the system If the manual controls display an error code that is not shown in the table, please contact your item branch or distribution partner...
Table Column Set E HD ESD ― Installation guide Maintenance and cleaning When operated under normal conditions and used for its intended purposes, the lifting system is maintenance-free for its entire service life. Consequently, there is no need for a service. CAUTION: Use only a dry or slightly damp cloth to clean the control system and the wired remote control.
Need help?
Do you have a question about the Table Column Set 2 E HD ESD 230V and is the answer not in the manual?
Questions and answers