3.
Move the IP Reset switch to the OFF position.
The network settings are restored. You can reconfigure the settings in MAX from a
computer on the same subnet. Refer to the Measurement & Automation Explorer Help for
more information about configuring the controller.
cRIO-9002/9004 Specifications
The following specifications are typical for the range -40 °C to 70 °C unless otherwise noted.
Caution
document. Product misuse can result in a hazard. You can compromise the safety
protection built into the product if the product is damaged in any way. If the product
is damaged, return it to NI for repair.
Network
Network interface
Compatibility
Communication rates
Maximum cabling distance

RS-232 Serial Port

Maximum baud rate
Data bits
Stop bits
Parity
Flow control
Memory
cRIO-9002
Nonvolatile
DRAM
cRIO-9004
Nonvolatile
DRAM
12 | ni.com | NI cRIO-9002/9004 User Manual and Specifications
Do not operate the cRIO-9002/9004 in a manner not specified in this
10Base-T and 100Base-TX Ethernet
IEEE 802.3
10 Mbps, 100 Mbps, auto-negotiated
100 m/segment
115,200 bps
5, 6, 7, 8
1, 2
Odd, Even, Mark, Space
RTS/CTS, XON/XOFF, DTR/DSR
64 MB
32 MB
512 MB