Daikin ETVZ16S18EA6V Installer's Reference Manual page 269

Hide thumbs Also See for ETVZ16S18EA6V:
Table of Contents

Advertisement

Field settings table
Breadcrumb
Field code
Setting name
9.I
[C-0D]
--
9.I
[C-0E]
--
9.I
[D-00]
Which heaters are permitted if prefer. kWh rate PS is cut?
9.I
[D-01]
Contact type of preferential kWh rate PS installation?
9.I
[D-02]
Which type of DHW pump is installed?
9.I
[D-03]
Leaving water temperature compensation around 0°C.
9.I
[D-04]
Is a demand PCB connected?
9.I
[D-05]
Is the pump allowed to run if prefer. kWh rate PS is cut?
9.I
[D-07]
Is a solar kit connected?
9.I
[D-08]
Is an external kWh meter used for power measurement?
9.I
[D-09]
Is an external kWh meter used for power measurement, kWh meter used for smart
grid or a gas meter for hybrid unit?
9.I
[D-0A]
--
9.I
[D-0B]
--
9.I
[D-0C]
--
9.I
[D-0D]
--
9.I
[D-0E]
--
9.I
[E-00]
Which type of unit is installed?
9.I
[E-01]
Which type of compressor is installed?
9.I
[E-02]
What is the indoor unit software type?
9.I
[E-03]
What is the number of backup heater steps?
9.I
[E-04]
Is the power saving function available on the outdoor unit?
9.I
[E-05]
Can the system prepare domestic hot water?
9.I
[E-06]
--
9.I
[E-07]
What kind of DHW tank is installed?
9.I
[E-08]
Power saving function for outdoor unit.
9.I
[E-09]
--
9.I
[E-0B]
Is a bi-zone kit installed?
9.I
[E-0C]
--
9.I
[E-0D]
Is the system filled with glycol ?
9.I
[E-0E]
--
9.I
[F-00]
Pump operation allowed outside range.
9.I
[F-01]
--
9.I
[F-02]
--
9.I
[F-03]
--
9.I
[F-04]
--
9.I
[F-05]
--
9.I
[F-09]
Pump operation during flow abnormality.
9.I
[F-0A]
--
9.I
[F-0B]
Close shut-off valve during thermo OFF?
9.I
[F-0C]
Close shut-off valve during cooling?
9.I
[F-0D]
What is the pump operation mode?
(*1) *6V_
(*2) *9W_
(*3) + EKHVCONV4
R/W
R/W
R/W
R/W
R/W
R/W
R/O
R/W
R/W
R/O
R/O
R/W (*3)
R/O
R/O
R/O
R/O
R/O
R/W
R/O
R/W
R/W
R/W
R/W
R/W
R/W
(#) Only applicable in Swedish language.
Range, step
Default value
0
0
0: None
1: BSH only
2: BUH only
3: All heaters
0: No
1: Active open
2: Active closed
3: Smart Grid
0: No DHW pump
1: Instant hot water
2: Disinfection
3: Circulation
4: Circulation and disinfection
0: No
1: increase 2°C, span 4°C
2: increase 4°C, span 4°C
3: increase 2°C, span 8°C
4: increase 4°C, span 8°C
0: No
1: Pwr consmp ctrl
0: Forced off
1: As normal
0: No
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
6: 100 pulse/kWh (PV meter)
7: 1000 pulse/kWh (PV meter)
8: 1 pulse/m³ (gas meter)
9: 10 pulses/m³ (gas meter)
10: 100 pulses/m³ (gas meter)
0
2
0
0
0
0~5
0: LT split
1
0: Reversible (*3)
1: Heating only
3: 6V (*1)
4: 9W (*2)
0: No
1: Yes
0: No
1: Yes
1
1: Integrated
0: disabled
1: Enabled
1
1: Yes
0
0: No
1: Yes
0
0: Disabled
1: Enabled
20
3
5
0
0
0: Disabled
1: Enabled
0
0: No
1: Yes
0: No
1: Yes
0: Continuous
1: Sample
2: Request
11/12
Installer setting at variance with
default value
Date
Value
4P644735-1 - 2021.02