Temperature adjustment with ambient temperature below +16°C
When the ambient temperature in the room in which the appliance is situa-
ted is less than 16° C, the ambient switch (B) must be depressed. The yellow
pilot light (A ) comes on. In this way, when the ambient temperature is low,
the compressor operates for longer periods to ensure that the storage tem-
perature of -18° C is maintained inside the freezer compartment.
Important!
If the ambient temperature rises to above +16°C, de-activate the ambient
switch in order to avoid unnecessary energy consumption. The yellow pilot
light goes out.

Starting up and temperature regulation

• Insert the plug of the connection lead into the plug socket with protecti-
ve earth contact.
Setting „0" means: Off.
Setting „1" means: Hightest temperature, (warmest setting).
Setting „4" (end-stop) means: Lowest temperature, (coldest setting).
However, the exact setting should be chosen keeping in the mind that the
temperature inside the refrigerator depends on:
-the quantity of food stored
-how often the door is opened
The temperatures in the refrigerator compartment and freezer co partment
cannot be independently regulated.
If you want the freeze fresh food rapidly, select setting „4", ensuring that
the temperature in the refrigerator compartment does not drop blow 0°C.
You should also promptly reset the temperature regulator to setting „2" or
„3".
Important!
High ambient temperatures (e.g. on hot summer days) and a cold setting on
the temperature regulator (position "4") can cause the compressor to run
continuously.
If this happens, turn the temperature regulator back to a warmer setting
(position "3" to "4"). At this setting the compressor will be switched on and
off as usual and automatic defrosting recommenced.