Specifications; Maintenance - Briggs & Stratton 030208 Operator's Manual

Table of Contents

Advertisement

Available languages

Available languages

SPECIFICATIONS

Starting Wattage . . . . . . . . . . . . . . . . . . . . . . .4,800 watts
Wattage . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3,500 watts
AC Load Current:
At 120 Volts . . . . . . . . . . . . . . . . . . . . . . . . .29.1 Amps
At 240 Volts . . . . . . . . . . . . . . . . . . . . . . . . .14.5 Amps
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–phase
Rated Frequency . . . . . . . . . . . . . . . . . . . . . . . . .60 Hertz
Fuel Tank Capacity . . . . . . . . . . . . . . . . . . . . 4 U.S. gallons
Shipping Weight . . . . . . . . . . . . . . . . . . . . . . . . . . 127 lbs.
GENERAL MAINTENANCE
RECOMMENDATIONS
The Owner/Operator is responsible for making sure that
all periodic maintenance tasks are completed on a timely
basis; that all discrepancies are corrected; and that the unit
is kept clean and properly stored. NEVER operate a
damaged or defective generator.
NOTE: Should you have questions about replacing
components on your BSPP generator, please call
1-800-743-4115 for assistance.
Engine Maintenance
See engine operator's manual for instructions.
CAUTION
Avoid prolonged or repeated skin contact with used
motor oil.
• Used motor oil has been shown to cause skin cancer in
certain laboratory animals.
• Thoroughly wash exposed areas with soap and water.
KEEP OUT OF REACH OF CHILDREN. DON'T
POLLUTE. CONSERVE RESOURCES. RETURN
USED OIL TO COLLECTION CENTERS.
3500W Portable Generator
Generator Maintenance
Generator maintenance consists of keeping the unit clean
and dry. Operate and store the unit in a clean dry
environment where it will not be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
slots in the generator must not become clogged with snow,
leaves or any other foreign material.
NOTE: DO NOT use a garden hose to clean generator.
Water can enter engine fuel system and cause problems. In
addition, if water enters generator through cooling air slots,
some of the water will be retained in voids and cracks of
the rotor and stator winding insulation.Water and dirt
buildup on the generator internal windings will eventually
decrease the insulation resistance of these windings.
WHEN ADJUSTING OR MAKING REPAIRS TO YOUR
GENERATOR
• Disconnect the spark plug wire from the spark plug and place
the wire where it cannot contact spark plug.
WHEN TESTING FOR ENGINE SPARK
• Use approved spark plug tester.
• DO NOT check for spark with spark plug removed.
Generator Cleaning
• Use a damp cloth to wipe exterior surfaces clean.
Improper treatment of generator can damage it and
shorten its life.
• DO NOT expose generator to excessive moisture, dust, dirt,
or corrosive vapors.
• DO NOT insert any objects through cooling slots.
• Use a soft bristle brush to loosen caked on dirt or oil.
• Use a vacuum cleaner to pick up loose dirt and debris.
• Inspect cooling air slots and opening on generator.These
openings must be kept clean and unobstructed.
13
WARNING
Unintentional sparking can result in fire or
electric shock.
CAUTION

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Elite series

Table of Contents