Installation Instructions; Flow Diagram - Hans Grohe PuraVida 15072000 Instructions For Use/Assembly Instructions

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 4
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal
pressures.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• If the water is flowing along the fixture in the direction
of the shaft, the spray former must be replaced with a
standard air bubbler 95928000.
• The drain valve must only be used as intended. It is not
allowed to attach other objects to the drain valve, for
example a semi-pedestal.
• The drain valve may only be installed in basins with
an overflow opening.
• If the instantaneous water heater causes problems or
if you wish to increase the water flow, the EcoSmart
(flow limiter) located behind the aerator can be
removed.
Special information for UK
If installing this product with a pump, please be aware
that it has to have negative head switching. This product
will not function with a positive head pump.
4
English
Technical Data
This mixer series-produced with EcoSmart
(flow limiter)
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
Symbol description
®
Assembly (see page 31)
(1 MPa = 10 bar = 147 PSI)
Do not use silicone containing acetic acid!
Dimensions (see page 32)

Flow diagram

(see page 33)
with EcoSmart
®
without EcoSmart
®
Spare parts (see page 35)
Operation (see page 34)
Hansgrohe recommends not to use as
drinking water the first half liter of water
drawn in the morning or after a prolonged
period of non-use.
Cleaning (see page 36)
Test certificate (see page 40)
®
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 70°C
65°C
max. 70°C / 4 min