• Certifications: cETLus UL 61010-1: 2012, IP42, 6 ft. Drop Protection • Battery Type: (AAA) 4 • Test Leads: Test leads w/ alligator clips Use ATL58 test leads w/ AAC3 alligator clips. ATL55, ATL57 and ATLTX will not work with DL589...
Important Safety Warnings WARNING Read entire Safety Notes section regarding potential hazards and proper instructions before using this meter. In this manual the word “WARNING” is used to indicate conditions or actions that may pose physical hazards to the user. The word “CAUTION” is used to indicate conditions or actions that may damage this instrument.
Symbols AC (Alternating current) DC (Direct current) Negative AC/DC Voltage or Current Auto-ranging Overload: Range Exceeded Auto power off Active Non-Contact Voltage Low Battery Hold/Capture Value Minimum measured Maximum measured value displayed value displayed Peak Min measured Peak Max measured P-MIN P-MAX value displayed...
Overview CAT IV 600V 600A DL589 Temp µA SELECT Low Z AUTO PEAK True RMS TEMP A. Clamp: Measure inductive AC/DC current. Opens to 1.25” (32.0mm). B. Conductor Alignment Marks: Use to aid the visual alignment of a conductor when measuring inductive amperage. Greatest accuracy is achieved when the conductor inside the clamp is centered at the intersection of these marks.
W. Battery Compartment Latches: X. Serial Number Low Z (Low Impedance) Low Z CAT IV 600V 600A DL589 • Rotate Selector Dial to Low Z Temp • Default = Auto Selection (AC or DC) µA • Press SELECT x1 = SELECT Low Z •...
Non-Contact Voltage NCV Sensor in the tip. CAT IV 600V 600A DL589 Temp µA SELECT Low Z AUTO PEAK True RMS TEMP • Rotate Rotary Selector Dial to NCV position move the tip of the clamp meter near voltage source.
1µA 45Hz to 400Hz True RMS Temperature Calibration The new DL589 clamp meter offers a digital field temperature calibration procedure to make the process easier. Here are the steps. 1) Set dial position to “°F°C” and check T1 mode 2) Press and hold SELECT button for about 2 seconds 3) Press HOLD button while “FCAL”...
Resistance: < 60MΩ CAT IV 600V 600A DL589 Temp µA • Default = SELECT Low Z • Press RANGE to select resolution AUTO PEAK True RMS TEMP Features: SELECT WARNING • Do not measure resistance on a live circuit. Range...
Voltage: 750V AC / 1000V DC CAT IV 600V 600A DL589 Temp High • Default = µA • Press SELECT= Voltage • Press RANGE to select resolution SELECT Low Z Alert AUTO PEAK True RMS TEMP WARNING • Use CATIII rated test leads or higher.
Frequency (Hz) / Duty Cycle CAT IV 600V 600A DL589 Temp µA • Default = • Press and hold ZERO x1 = SELECT Low Z • Press and hold ZERO x2 = • Press RANGE to select resolution AUTO PEAK...
• Readings show on upper display PEAK True RMS TEMP The UEi LRA Inrush is programmed to properly capture the starting current for compressor motors. • Select AC Amps. • Select the range capable of capturing the maximum value. • Press the ZERO button – INRUSH will now be shown on the screen.
CAUTION: If the test leads need to be replaced, you must use a new one which should meet EN 61010-031 standard, rated CATIII 1000V or better. NOTE: DL589 works with UEi ATL58 test leads and AAC3 alligator clips. Battery Replacement •...
Any implied warranties, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the express warranty. UEi shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expenses or economic loss.