VI) SPECIFICATIONS
Input:
115/230 VAC + 10%, 50-60 Hz.
Output:
13.8 VDC
20 Amps Surge (10% duty cycle, 10 minutes max.)
5 Amps continuous (100% duty cycle)
Regulation:
1% Line and Load
Ripple:
4 mV RMS (@5 amp continuous duty rating)
Current Limit:
Power supply current limit set @ 110% of continuous
duty rating.
Low Voltage Alarm:
Engages @ 10.6 - 10.9 VDC Output
Terminal Voltage
Low Voltage Disconnect: 10.3 VDC Output Terminal Voltage
Internal Battery(s): Sealed, Lead-Acid, Rechargeable, Deep-Cycle
12 Volt, 7 Amp-Hour
Back-Up Battery Float Voltage: 13.8 VDC
Dimensions (H x W x D): 5.25" x 9" x 10.5"
Weight:
16 Ibs. (with one battery)
22 Ibs. (with two batteries)
8
POWER-PAC
INSTALLATION / OPERATION
MANUAL
1
R

Advertisement

loading

Summary of Contents for NewMar POWER-PAC

  • Page 1 VI) SPECIFICATIONS POWER-PAC Input: 115/230 VAC + 10%, 50-60 Hz. Output: 13.8 VDC INSTALLATION / OPERATION 20 Amps Surge (10% duty cycle, 10 minutes max.) 5 Amps continuous (100% duty cycle) MANUAL Regulation: 1% Line and Load Ripple: 4 mV RMS (@5 amp continuous duty rating)
  • Page 2 Override Button. up with the addition of another internal or external battery. If the Power-Pac is already connected to the radio when AC power fails, engagement of the battery back-up is automatic. However, there may be II) FEATURES occasion to install the Power-Pac when there is no AC power available initially.
  • Page 3 If you require the Power-Pac to operate at 230 VAC input, take the following steps terminals. If you install a second battery, be sure to mark the box next to the 14 before you apply AC power: amp-hour ratings in the matrix on the bottom of the unit.
  • Page 4 This light, located directly above the On/Off switch will III) FEATURES ILLUSTRATION illuminate when there is AC available to the Power-Pac and the switch is in the “On” position. It is unrelated to DC output. For this illustration, refer to section IV) A, B, C: 3.