Fault During Connection Set-Up And Search - Kaco blueplanet 3.0 NX3 M2 Manual

Photovoltaic feed-in inverter
Hide thumbs Also See for blueplanet 3.0 NX3 M2:
Table of Contents

Advertisement

No.: W165
Description
Step
PE connection error
1
This error occurs when the inverter detects overvoltage in the N-PE.
2
Using the multimeter, measure the N-PE voltage of the device.
3
Ensure that the earth cable is firmly connected and that the connection area is sufficient.
4
If the error persists, please contact KACO new energy customer service.
10.6

Fault during connection set-up and search

Note: If there is a timeout or a communication failure with its WLAN network, the
APP may freeze in an unwanted manner.
We recommend the following approach:
-
Check the WLAN connection on the mobile end device. If the
connection has been lost, reactivate it in the device settings. The
window of the "KACO NX Setup" APP has to be closed completely
using the overview of all opened windows, so that the "KACO NX
Setup" APP can be restarted.
-
If necessary, restart the search using the "Scan" button.
-
If the QR code is not recognized, a manual connection to the
communication unit can be established in the settings of the WLAN
connection on the mobile end device. SSID: Serial number WIFI
stick, password: Registration code (both printed on WIFI stick) see
Fig. 50.
The current connection status can also be checked using the LEDs on the
Note:
WIFI stick.
To do this, check the signal status by referring to Chapter 9.4 on
» Faults have been corrected and the status LED on the communication unit
page 27.
lights up continuously, signalling readiness for operation.
KACO blueplanet 3.0 NX3 M2 KACO blueplanet 5.0 NX3 M2 KACO blueplanet 8.0 NX3 M2 KACO blueplanet 10.0 NX3 M2
KACO blueplanet 15.0 NX3 M2 KACO blueplanet 20.0 NX3 M2
Fig. 142. Fault during connection &
search
Page 62

Advertisement

Table of Contents
loading

Table of Contents