Installation - Graco G Series Instructions-Parts List Manual

2:1 ratio standard pump
Table of Contents

Advertisement

General Information
1. The Typical Installation shown in Fig. 2 is only a guide
for selecting and installing system components.
Contact your Graco distributor for assistance in
planning a system to suit your needs.
2. Always use Genuine Graco Parts and Accessories.
3. Reference numbers and letters in parentheses refer
to the callouts in the figures and the partslists on
pages 12 through 15.
Grounding the System
WARNING
FIRE AND EXPLOSION HAZARD
This pump must be grounded. Before
operating the pump, ground the system as
explained below. Also read the section
FIRE AND EXPLOSION HAZARD on
page 3.
To reduce the risk of static sparking, ground the pump and
all other equipment used or located in the pumping area.
Check your local electrical code for detailed grounding
instructions for your area and type of equipment. Ground
all of this equipment.
1. Pump: connect a ground wire and clamp as shown in
Fig. 1. Loosen the air motor shield retaining screw
(X). Connect one end of a 12 ga (1.5 mm) minimum
ground wire (Y) to the screw (X) and tighten the screw
securely. See Fig. 1. Connect the other end of the
wire to a true earth ground. See the ACCESSORIES
section to order a ground wire and clamp.
4
307026

Installation

Fig. 1
2. Air compressor: according to manufacturer's
recommendations.
3. Fluid hoses: use only grounded hoses with a
maximum of 500 ft (150 m) combined hose length to
ensure grounding continuity. Refer to Hose
Grounding Continuity.
4. Dispensing valve: grounding is obtained through
connection to a properly grounded fluid hose and
pump.
5. Object being sprayed: according to local code.
6. Fluid supply container: according to local code.
7. All solvent pails used when flushing, according to
local code. Use only metal pails, which are
conductive. Do not place the pail on a non-conductive
surface, such as paper or cardboard, which interrupts
the grounding continuity.
8. To maintain grounding continuity when flushing or
relieving pressure, always hold a metal part of the
spray gun/dispensing valve firmly to the side of a
grounded metal pail, then trigger the gun/valve.
X