Category
Maximum fluid working pressure
Air input pressure operating range
Pump cycles per 1 gallon (3.8 liters)
Maximum recommended pump speed for
continuous operation
Air consumption
Maximum Ambient temperature for T6
hazardous location use
Maximum Fluid temperature for T6
hazardous location use
Wetted parts
Sound Pressure
Sound Power, per ISO 9614–2
20
307026

Technical Data

Data
360 psi (25 bar)
30-180 psi (2-12 bar)
40 (50 for Model 223954)
100 cycles per min
approx. 3 scfm (0.09 m#/min) at 1 gpm (3.8 liters/min) at 100 psi (7
bar) air pressure
120 F (50 C)
180 F (82 C)
Stainless Steel, PTFE, Polyetheretherketone (PEEK)
88.7 dB(A) @ 80 psi (550 kPa, 5.5 bar)
96.8 dB(A) @ 80 psi (550 kPa, 5.5 bar)