IP Address Method
Auto*, Static
Possible Values:
This item controls how the optional Ethernet interface card receives its network address. When set to
Auto, the Ethernet card will receive its network address from a network DHCP server (typical
installation). When set to Static, the user sets the TCP/IP address, Subnet Mask and TCP/IP Gateway
address as follows:
IP Address
000.000.000.000 ... 255.255.255.255
Possible Values:
To set the TCP/IP address, use the SUBMENU key to select which digit group you wish to change, and
then use the UP/DOWN ARROW keys to change the value. The value will change rapidly if the key is held
down.
Subnet Mask
Possible Values:
000.000.000.000 ... 255.255.255.255
To set the Subnet Mask, use the SUBMENU key to select which digit group you wish to change, and then
use the UP/DOWN ARROW keys to change the value. The value will change rapidly if the key is held down.
Gateway Address
000.000.000.000 ... 255.255.255.255
Possible Values:
To set the TCP/IP Gateway address, use the Submenu key to select which digit group you wish to change,
and then use the UP/DOWN ARROW keys to change the value. The value will change rapidly if the key is
held down.
Automatic Carriage Return
Off, On*
Possible Values:
This item enables or disables automatic Carriage Returns (CR) whenever a Line Feed (LF), Vertical Tab
(VT), or Form Feed (FF) is received.
Automatic Line Feed
Possible Values:
Off*, On
This item enables or disables automatic Line Feeds (LF) when a Carriage Return (CR) is received.
P R I N T E R
IP Address
Auto
IP Address
192.160.0.27
Subnet Mask
255.255.255.0
IP Gateway
192.168.0.0
Auto CR
On
Auto LF
Off