Available languages

Available languages

To decrease the power level press key
− Three green LEDs
5
show positions one to three.
6
− The red LED
shows the Power position. The Power
position is only used if there are strong odours, or a lot
of smoke or vapour. Its use must be kept to a minimum
because of the large extraction of air in this position.
− The Power position automatically goes back to speed
three after 6 minutes.
− The motor has a thermal switch that switches the motor
off with overheating. After cooling the motor will switch
on again.

Determining the cause of overheating is re-
quired. This can be caused for example by a
pan fire, the impeller motor being blocked or
an object getting in the exhaust opening and
causing it to be partly or fully blocked.
Auto-Stop
To avoid the extractor hood from staying on, the motor is
automatically switched off after 3 hours (only if in 3 hours
operation has not been changed). The extractor hood
lighting stays on.

2.3 Lighting

Turning the lighting on and off
To turn the lighting on or off press
The light works independent of the motor.
The LED lighting has a soft on/soft off mode, which means
that the lighting will evenly go on and off. When switching
on the lighting, this will always light up with full power and
it can also be used when the fan is off.
Dimming LED lighting
When the LED lighting has been switched on, it can be
dimmed by keeping key
Change in colour temperature with LED-lighting
You can change the colour temperature of the LED-lighting
form 2.700 K (warm white) into 4.000 K (neutral white). The
description for changing this can be found in section 3.4.
.
2
.
4
pressed.
4

2.4 Programming recirculation (optional)

If recirculation is selected programming must
take place once.
This programming function activates the replacement
indicator of the monobloc recirculation filter and the delay
time is changed.
Activating programming
− The motor must be switched off
− Press the
and the
2
seconds until the red LED flashes 5 times.
The following functions then operate:
− Replacement indicator of the monobloc filter is activated.
After a set time a red indicator light on the appliance
shows that the monobloc filter must be replaced.
− The delay time is set to 30 minutes (instead of the default
10 minutes).
Use the delay time of 30 minutes so the
cooking odours can be properly removed in
the monobloc filter.
Read paragraph 3.3 for more information about replacement
of the monobloc recirculation filter.
Deactivating programming
− The motor must be switched off
− Press
and
2
3
the 3rd green LED flashes 3 times.
The delay time is again set to 10 minutes (instead of 30 min-
utes) and cleaning indicator for recirculation is switched off.