Controls And Functions; Operating The Device; Turning The Extraction On And Off; Lighting - Novy Flat'line 7602 User Manual

Table of Contents

Advertisement

Available languages

Available languages

2 CONTROLS AND FUNCTIONS

2.1 Operating the device

2.1 Operating the device
1
Switch on / off
2
Decrease speed level
3
Increase speed level
4
Illumination
5
Indication lights green speed 1,2,3
6
Indication light red Power mode
2.2 Turning the extraction on and off
Turning the extraction on off
Press button
1
to turn on the extractor. The extractor
always starts in the function last used (lighting and/or motor).
Turning the extraction off with delay mode
To set delay mode press key
The fi rst indicator light fl ashes, the other indicator lights
come on at the last position set. After 10 minutes the motor
and lighting automatically switch off.
The delay time is set by default to 10 minutes in extraction
mode. It is advised to always fully allow this function to work.
Switching extraction off without delay mode
Press key
twice.
1
Extractor power level
To increase the power level press key
To decrease the power level press key
once.
1
3
.
.
2
− Three green LEDs
6
− The red LED
position is only used if there are strong odours, or a lot
of smoke or vapour. Its use must be kept to a minimum
because of the large extraction of air in this position.
− The Power position automatically goes back to speed
three after 6 minutes.
− The motor has a thermal switch that switches the motor
off with overheating. After cooling the motor will switch
on again.

Determining the cause of overheating is re-
quired. This can be caused for example by a
pan fi re, the impeller motor being blocked or
an object getting in the exhaust opening and
causing it to be partly or fully blocked.
Auto-Stop
To avoid the extractor hood from staying on, the motor is
automatically switched off after 3 hours (only if in 3 hours
operation has not been changed). The extractor hood
lighting stays on.

2.3 Lighting

Turning the lighting on and off
To turn the lighting on or off press
The light works independent of the motor.
The LED lighting has a soft-on/soft-off function, meaning the
lighting will go gently on and off.
When switching the lighting on it will always go to full
power and can also be used when the fan is switched off.
Dimming the LED lighting
When the LED lighting is switched on you can dim it by
keeping key
pressed.
4

2.4 Programming recirculation (optional)


Model 7605 / 7615 - This cooker hood, which
is connected to an external motor from Novy,
can only be used with an extraction duct to the
outside and is not suitable for recirculation.
If recirculation is selected programming must
take place once.
This programming function activates the replacement
indicator of the monobloc recirculation fi lter and the delay
time is changed.
– 36 –
5
show positions one to three.
shows the Power position. The Power
.
4

Advertisement

Table of Contents
loading

Table of Contents