B. Retrofit from a double wall pipe to a shielded single wall pipe
The HEATFLOW S5 can only be used with SINGLE WALL PIPE
A pipe section can only have 1 single pipe shield
From Single wall pipe (DIMENSION "B")
CLEARANCE FROM SINGLE WALL PIPE SHIELD TO COMBUSTIBLE MATERIALS FOR
To Ceiling (DIMENSION "A")
To Wall (DIMENSION "D")
*** note: For products other than SBI Heating Accessories, the clearance is 9"
•
The retrofit of a double wall pipe to a single one can be done by placing a pipe shield on part of the pipe
at places where the clearance from combustible materials is less than 18in (0.46m).
•
The clearances with the use of a pipe shield are presented in table above.
•
The retrofit with a pipe shield may require the user to move the stove away from the wall (Dimension
"C").
Next schematic is for reference:
Installation Instruction HEATFLOW S5
WARNING
CLEARANCE TO COMBUSTIBLE MATERIALS
APPROVED SBI HEATING ACCESSORIES
English
CANADA
9" MIN
6"*** MIN
18in MIN
U.S.
9" MIN
6" MIN
46310A
2023-05-25