Apply the lubricant
supplied for ease of
assembly (do not
use any other type).
Ensure Elbow is
fully engaged into
Boiler Adaptor
Apply the lubricant
supplied for ease of
assembly (do not use
any other type).
Ensure Flue is fully
engaged into Elbow
7726858-01 (1/19)
Boiler Adaptor
Gasket
Fig. 28
Adaptor
Fig. 29
Fig. 30
Slots at bottom
Fig. 31
10. Remove the boiler blank adaptor and replace with the boiler
adaptor ensuring that the gasket is in position. Replace the
gasket if necessary (Fig. 28).
11. Insert the flue through the hole in the wall. Fit the elbow to
the boiler adaptor, ensuring that it is pushed fully in (Fig. 29).
12. Draw the flue back through the wall and engage it in the
elbow. It may be necessary to lubricate to ease assembly of the
elbow and flue (Fig. 30).
13. Ensure that the terminal is positioned with the slots to the
bottom (Fig. 31). Secure the flue to the elbow with the screws
supplied (Fig. 30).
It is essential that the flue terminal is fitted as shown to
ensure correct boiler operation and prevent water
entering the flue. There must be no part of the air duct
(white tube) visible outside the property after
installation.
14. Make good between the wall and air duct outside the
building, appropriate to the wall construction and fire rating.
15. If necessary fit a terminal guard (see Section 5.3.11).
Installation
6
600 Heat
37