SPECIFICATIONS

Unit Weight
Shipping Weight
Capacity: AHAM DH-1-2008 80°F, 60% RH Conditions
Power: 115 VAC, Single Phase, 60Hz
Dehumidifier Inlet Air Conditions
Filter
Airflow

SET UP DEHUMIDIFIER FOR INSTALLATION

IMPORTANT:
Cut the strap securing the compressor
shipping support bracket and remove the strap and shipping bracket .
See Figure 1 .

PACKAGING CONTENT

1 . Dehumidifier
2 . Inlet/Outlet Collars
3 . Literature
a . Installation Instructions
b . Owner's Manual
4 . Parts Bag
a . #10 x 1/2 Screws (9)
b . Threaded Barbed Fitting for Drain
Connections
c . Torx Bit
5 . 10 foot, 3/4" Drain Tube

DUCT COLLARS

Use the screws in the parts bag to attach the duct
collars to the inlet and outlet of the dehumidifier .
See Figure 2 .
2
70 pints per day @ 200 CFM
5 .8 Amps operating current
Dehumidification: 50°F – 104°F, 40°F dew point minimum
Ventilation: 40°F – 140°F, 0%RH – 99%RH (non-condensing)
FIGURE 1 – Remove Shipping Bracket
FIGURE 2 – Install Duct Collars
INLET
DUCT
COLLAR
Model E070
56 lbs .
72 lbs .
MERV 8, washable
200 CFM
REMOVE SHIPPING BRACKET
CLIP OFF
PLASTIC
STRAP
90-2302
OUTLET
DUCT
COLLAR
90-2308