SYSTEM SET-UP, CHECK & START-UP

VENTILATION / AIR CYCLING

90-1854
90-1854
90-1854
90-1854
(CONTINUED)
If not using the dehumidifier to
periodically cycle air in the crawl
space, press MODE to go to ZONE
screen selections .
If using the dehumidifier for air
cycling, Enable and press MODE .
Press MODE at the VENT TIMED
screen to go to ventilation time
selection screen .
Press the UP or DOWN arrows
to adjust the ventilation time
per hour from 0 to 60 minutes .
After selecting time, press
MODE . Press MODE through the
ZONE, EXTERNAL, DEH w/AC,
and RH offset screens . DONE
will be displayed on the screen
and Installer Set-up is complete .
Proceed to SYSTEM CHECK . on
page 7 .

SYSTEM CHECK

90-1854
90-1854
90-1854
90-1854
Press and hold the ON/OFF button
and MODE buttons for 3 seconds .
The measured humidity, AIR
SAMPLING and TEST will show on
the display .
After three (3) minutes the
dehumidifier compressor will
turn on and DEHUMIDIFYING will
replace AIR SAMPLING on the
control screen .
After one minute of compressor
operation, all outputs will turn off
and DONE will blink for 3 seconds
and then return to the OFF screen .