System Set-Up, Check & Start-Up; Remote Control - Crawl Space - Aprilaire E070 Installation Instructions Manual

Hide thumbs Also See for E070:
Table of Contents

Advertisement

SYSTEM SET-UP, CHECK & START-UP
If using a Model 76 Remote Control and/or the Air Cycling feature,
proceed to Step 1 below . If not using either feature, proceed to
SYSTEM CHECK on page 7 .
1. Check all wiring .
2. Make sure the wire access cover has been snapped back onto the
on-board control .
3. Plug unit in and turn power switch to ON . The power switch is
located on the dehumidifier outlet next to the power cord .
4. The on-board control screen should display OFF .
90-1854
NOTE: If the display backlight is not on, the first button press (any
button) will only turn on the backlight . Press the button a second time
to achieve function .
5. Hold the MODE button on the on-board control for 3 seconds to
enter the Installer Set-up Menu .
6. Navigate through the following screens to set up the dehumidifier
for the installed application .
Use the UP or DOWN arrows to select items and use MODE to
switch to the next set-up option . To exit installer set-up, all options
must be scrolled through using the MODE button .
7. After the installer set up options have been completed, DONE will
blink for 3 seconds and the control will return to the OFF screen .
90-1854
6
REMOTE CONTROL – CRAWL SPACE
90-1854
If not installing in a crawl space
with Model 76 remote control,
press MODE to go to VENT screen
selections
90-1854
If installing in a crawl space with
remote control, Enable and press
MODE . The installer set-up is
complete, proceed to SYSTEM
CHECK on page 7 .
90-1854
NOTE: Air Cycling is not an
option when Remote is enabled .

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents