Specifications; Preparing The Unit For Installation - Aprilaire E080 Installation And Owner's Manual

Hide thumbs Also See for E080:
Table of Contents

Advertisement

SPECIFICATIONS

Unit Weight
Capacity
80°F, 60% RH Conditions
Power
115 VAC, Single Phase, 60 Hz
Dehumidifier Inlet Air Conditions
Filter
Airflow
N
OTE:
Rated capacity and current draw measured
at 80°F/60% RH inlet conditions at 0.0 external static
pressure.
PREPARING THE UNIT FOR
INSTALLATION
IMPORTANT: Cut the strap securing the compressor
shipping support bracket and remove the strap and
shipping bracket . See Figure 8 .
1 .
Clip off and remove the plastic straps securing the
compressor to the shipping bracket .
2 . Remove the two screws securing the shipping
bracket to the housing . Remove and discard the
shipping bracket, and reinstall the two screws in the
dehumidifier .
6 English
Model E080
63 lbs .
80 pints per day @ 185 CFM
5 . 1 A operating current
Dehumidification: 50°F–104°F, 40°F dew point minimum
Ventilation: 40°F–140°F, 0% RH–99% RH (non-condensing)
MERV 8, washable
External Static
Airflow (CFM)
Pressure ("WC)
0 . 0
185
0 . 2
135
0 . 4
85
Figure 8: Preparing the Unit for Installation
1 - Clip Off Plastic Strap
Model E100
64 lbs .
100 pints per day @ 280 CFM
6 . 9 A operating current
External Static
Airflow (CFM)
Pressure ("WC)
0 . 0
280
0 . 2
245
0 . 4
210
0 . 6
175
2
1
90-1908
2 - Remove Shipping
Bracket

Advertisement

Table of Contents
loading

This manual is also suitable for:

E100

Table of Contents