Connecting a USB cable
Saved measurement logs, photos and videos can be transferred
to a PC with the supplied USB cable.
To connect the USB cable to the device, proceed as follows:
1. Open the rubber side cover.
2. Connect the USB cable to the device.
Maintenance and repair
Warning of laser radiation
Laser class 1
The laser is encapsulated.
Do not open the device to prevent direct contact with
the laser and the emitted radiation!
Cleaning
Clean the device with a soft, damp and lint-free cloth. Ensure
that no moisture enters the housing. Do not use any sprays,
solvents, alcohol-based cleaning agents or abrasive cleaners,
but only clean water to moisten the cloth.
Repair
Do not modify the device or install any spare parts. For repairs
or device testing, contact the manufacturer.
Charging the battery
The battery is partially charged upon delivery to avoid damage
to the battery caused by a deep discharge.
Warning of electrical voltage
Before each use of the charger or power cable, check
for damages. If you notice damages, stop using the
charger or power cable!
Note
The battery can be damaged in case of improper
charging.
Remove the charger's mains plug before inserting or
removing the battery.
Never charge the battery at ambient temperatures
below 10 °C or above 40 °C.
The battery should be charged prior to initial start-up and when
the battery is low. To do so, please proceed as follows:
EN
1. Open the rubber side cover.
2. Attach the charger.
3. The loading screen is shown on the display. When the
battery is fully loaded, the battery symbol is completely
green.
Deleting data
To remove saved data from the internal memory or the microSD
card, proceed as follows:
1. Press "F2" in the start screen.
ð The
SYSTEM SET
2. Use the
and then press "ENTER" to confirm.
ð The
Memory Status
3. Use the
or the microSD card.
ð The memory usage is shown below the selection.
4. Press "F1"
memory.
ð Press "F1" again to confirm the deletion.
ð Press "F3"
5. Press ESC to exit the menu.
Resetting factory settings
To return the device to the state it was in when it left the
factory, proceed as follows:
1. Press "F2" in the start screen.
ð The
SYSTEM SET
2. Use the
and then press "ENTER" to confirm.
ð The
Factory Setting
3. Press
ð The device is reset to factory settings.
ð Photos, videos and measurement logs on the internal
memory or on the microSD card remain unaffected.
Operating manual – particle counter PC 200
menu opens.
keys to select the
"Memory
menu opens.
keys to select either the device memory
to start deleting all data from the selected
to cancel the deletion.
menu opens.
keys to select the
"Factory
menu opens.
once and confirm by pressing "ENTER".
Status" menu
Setting" menu
10