Introduction

About the water heater

The HWHC water heater is intended for heating water for sanitary purposes.
The HWHC is a condensing gas–fired storage water heater with a fan in the air intake. The
flue gasses transfer their heat to the water through an efficient heat exchanger. The water
heater has a concentric venting connector and can function as an open or as a room-
sealed water heater.
The water is heated partly by means of the heat exchanger in the bottom of the tank. This
heat exchanger can be connected to e.g. a solar energy source.

The appliance's heating cycle

The appliance's heating cycle is activated when the measured water temperature (T
below the threshold value (T
appliance operating mode. For example, if the appliance is in OFF mode (frost
protection), then this value is 5°C. If the appliance is in ON mode, this threshold value is
adjustable, for example to 65°C.
The heating cycle runs successively through the following states:
HEAT DEMAND;
PRE-PURGE;
PRESSURE SWITCH;
PRE-GLOW;
IGNITION;
RUNNING;
POST-PURGE.

Working principle

The water heater is fitted with a modulating premix burner system with 1:1 gas-to-air
ratio regulation. The air required for combustion is delivered by the fan (18). The gas is
supplied via the gas control valve (16) and the venturi (30) on the intake side of the fan.
The 1:1 gas-to-air ratio always guarantees the most efficient gas/air mixture.
In this water heater, the cold water enters the bottom of the tank through the cold water
inlet (14). The water is heated by means of a heat exchanger (55) connected to a solar
heating system and a gas-fired heat exchanger (11). The heated tap water leaves the tank
through the hot water outlet (2). Once the water heater is completely filled with water, it
will constantly be under mains water pressure. As hot water is drawn from the water
heater, cold water is immediately added.
The special design of the heat exchanger (11) ensures that the flue gases are first led
downwards via the combustion chamber, then upwards via the heat exchanger, and
downwards again alongside the water in the tank. The flue gases gradually become cooler
in the process. Because the cooled flue gases flow alongside the cold water lower down in
the tank, they start to condense. This condensation causes latent heat energy to be
). This threshold value depends on the currently selected