Page 2
MOV instruction (Please refer to allocation of special registers D9900 ~ D9999). EN DVP04AD-E2 is an OPEN-TYPE device. It should be installed in a control cabinet free of airborne dust, humidity, electric shock and vibration. To prevent...
Note 5: If the ripples at the loaded input terminal are too significant that causes noise interference on the wiring, connect the wiring to 0.1 ~ 0.47μF 25V capacitor. I/O Terminal Layout VI1- VI2- VI3- DVP04AD-E2 (4AI) VI4- Electrical Specifications Analog / Digital module (04A/D) Power supply voltage 24VDC (20.4VDC ~ 28.8VDC) (-15% ~ +20%)
Attrib. Register name Explanation Set up by the system: Model name DVP04AD-E2 model code = H’0080 Firmware version Display the current firmware version in hex. Input mode: Default = H’0000. O R/W CH1 input mode setting Take CH1 for example: Mode 0 (H’0000): Voltage input (±10V)
Page 5
Set the adjusted Offset value of CH1 ~ CH4. Default = K0 #29 O R/W Adjusted Offset value of CH2 Definition of Offset in DVP04AD-E2: #30 O R/W Adjusted Offset value of CH3 The corresponding voltage (current) input value when the digital output value = 0.
Page 6
When DVP-ES2 MPU is connected with modules, registers D9900~D9999 will be reserved for storing values from modules. You can apply MOV instruction to operate values in D9900~D9999. When DVP-ES2 MPU is connected with DVP04AD-E2, the configuration of special registers is as below: Module...
Page 7
Users can adjust the conversion curves according to the actual needs by changing the Offset value (CR#28 ~ CR#31) and Gain value (CR#34 ~ CR#37). Gain: The corresponding voltage/current input value when the digital output value = 16,000. Offset: The corresponding voltage/current input value when the digital output value = 0. ...
Page 8
Mode 2: Mode 3: +32384 +32384 +32000 +32000 Digital Digital output output +16000 +16000 Gain Gain 2.5V -384 -384 Offset Offset Voltage input Voltage input Mode 2 of CR#2 ~ CR#5 0V ~ +10V, Gain = 5V (16,000), Offset = 0V (0) Mode 3 of CR#2 ~ CR#5 0V ~ +5V, Gain = 2.5V (16,000), Offset = 0V (0) 0 ~ +32,000...