de vérifier encore une fois le câblage avant la mise sous tension du DVP06XA-S/DVP06XA-S2. Lors de la déconnection de l’appareil, ne pas toucher les connecteurs dans la minute suivante. Vérifier que la terre est bien reliée au connecteur de terre afin d’éviter toute...
Response time 3ms × Number of channels DVP06XA-S: The analog circuit and the digital circuit are grounded together. There is no isolation. Isolation method DVP06XA-S2: The analog circuit is isolated from the digital circuit by an optocoupler, but the analog channels are not isolated from one other.
Page 4
Latched Register name address For system use Data length: 8 bits (b7 ~ b0) Model code of DVP06XA-S: H’CC H’40C8 ○ Model type Model code of DVP06XA-S2: H’D4 Users can read the model type by means of a program to check if the extension module exists.
Page 5
16584 and then adding one to it, you have 16585, the Modbus address in decimal format. ※ DVP06XA-S CR#32 communication format settings: for modules with firmware V4.12 or previous versions, b11~b8 data format selection is not available. For ASCII mode, the format is fixed to 7, E, 1 (H’00XX) and for RTU mode, the format is fixed to 8, E, 1 (H’C0xx/H’80xx). For modules with firmware V4.13 or later, refer to the following table for setups.
Page 6
b15 ~ b12 b11 ~ b8 b7 ~ b0 ASCII/RTU Data format Baud rate exchange low and high byte of CRC check code Description ASCII 7,E,1* H'01 4800 bps RTU, 8,E,1 H'02 9600 bps do not exchange low and high byte of 7,N,1* H'04 19200 bps...