5. Remove two stop rings from the original feed belt shaft A
and then remove the bushing, pulley, spring pin, original
feed holder and original feed color A.
6. Remove the original feed belt shaft A from the original feed
belt unit.
7. Remove the original feed belt shaft B from the original feed
belt unit.
8. Remove the original feed color B and DP original feed belt
from original feed belt shaft B.
9. Remove two stop rings from the forwarding
pulley shaft and then remove two pulleys,
two spring pins and two bushings.
10. Pull out the forwarding pulley shaft and
remove the DP forwarding pulley.
11. Replace the DP original feed belt and DP
forwarding pulley.
12. Install the DP forwarding pulley to the origi-
nal feed unit.
13. Install the DP original feed belt to the origi-
nal feed belt unit.
14. Refit the original feed belt unit to the original
feed unit.
15. Refit the original feed unit to the DP.
Y106871-5
Stop ring
Bushing
Pulley
Spring pin
Original feed holder
Original feed color A
Original feed belt shaft B
Stop ring
Figure 1-5-4
Stop ring
Spring pin
Pulley
Bushing
Forwarding
pulley shaft
DP forwarding pulley
Service Manual
Original feed color B
DP original feed belt
Original feed
belt unit
Original feed
belt shaft A
Original feed unit
Spring pin
Figure 1-5-5
3JX
Bushing
Pulley
Stop ring
1-5-3