Maintenance
item No.
U411
When automatic adjustment has normally completed, [RESULT OK 00] is displayed. If a problem
occurs during auto adjustment, [ERROR XX] (XX is replaced by an error code) is displayed and opera-
tion stops. Should this happen, determine the details of the problem and either repeat the procedure
from the beginning, or adjust the remaining items manually by running the corresponding maintenance
items.
Method: ORIGINAL TARGET
1. Place the specified original for acquiring gamma target data (P/N: AVGR05133T) on the platen, and
press the start key.
2. Place the specified original for acquiring matrix target data (P/N:
the start key.
3. Select the item.
Display
ALL
INPUT
GAMMA
MTF/MATRIX
[ALL]
1. Set specified originals (P/N: AVGR05132X / AVGR05133T / AVGR05134Q) in the DP.
Stack the originals in the order of AVGR05132X, AVGR05133T and AVGR05134Q.
2. Press the start key. Auto adjustment starts.
[INPUT]
1. Set a specified original (P/N: AVGR05132X) in the DP.
2. Press the start key. Auto adjustment starts.
[GAMMA]
1. Set a specified original (P/N: AVGR05133T) in the DP.
2. Press the start key. Auto adjustment starts.
[MTF/MATRIX]
1. Set a specified original (P/N: AVGR05134Q) in the DP.
2. Press the start key. Auto adjustment starts.
When automatic adjustment has normally completed, [RESULT OK 00] is displayed. If a problem
occurs during auto adjustment, [ERROR XX] (XX is replaced by an error code) is displayed and opera-
tion stops. Should this happen, determine the details of the problem and either repeat the procedure
from the beginning, or adjust the remaining items manually by running the corresponding maintenance
items.
Y106871-5
Description
Automatic adjustment of second page using the DP
for: original size magnification/leading edge timing/
center line, input gamma, chromatic aberration filter,
MTF filter and matrix.
Automatic adjustment of second page using the DP
for: original size magnification/leading edge timing/
center line.
Automatic adjustment of second page using the DP
for: input gamma.
Automatic adjustment of second page using the DP
for: MTF filter and matrix.
Service Manual
Description
AVGR05133T
) on the platen, and press
Original to be used for
adjustment (P/N)
AVGR05132X/AVGR05133T/
AVGR05134Q
AVGR05132X
AVGR05133T
AVGR05134Q
3JX
1-3-15