Extension Cords
Use an extension cord with an undamaged
ground contact. If an extension cord is
necessary, use a 3-wire, 12 AWG (2.5 mm²)
minimum.
NOTE: Smaller gauge or longer extension
cords may reduce sprayer performance.
Grounding of Pails
Solvent pails used when flushing: Follow
local code. Use only conductive metal pails,
placed on a grounded surface. Do not place
the pail on a non-conductive surface, such as
paper or cardboard, which interrupts
grounding continuity.
334606J
Always ground a metal pail: connect a
ground wire to the pail. Clamp one end to the
pail and the other end to a true earth ground
such as a water pipe.
To maintain ground continuity when
sprayer is flushed or pressure is relieved:
hold metal part of spray gun firmly to the side
of a grounded metal pail then trigger the gun.
ti25360a
Circuit Protection
Connect sprayers only to circuits which have
the properly sized circuit breaker and/or
fuses (for unit power requirements see
Technical Data, pages 60-63).
Grounding
ti24585a
15