Advertisement

Quick Links

USER MANUAL
ENGLISH
TED Pack Single, FR output
V1
Product code: 50444FR
Highlite International B.V. – Vestastraat 2 – 6468 EX – Kerkrade – the Netherlands

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TED Pack Single FR output V1 and is the answer not in the manual?

Questions and answers

Summary of Contents for SHOWTEC TED Pack Single FR output V1

  • Page 1 USER MANUAL ENGLISH TED Pack Single, FR output Product code: 50444FR Highlite International B.V. – Vestastraat 2 – 6468 EX – Kerkrade – the Netherlands...
  • Page 2 TED Pack Single, FR output Preface Thank you for purchasing this Showtec product. The purpose of this user manual is to provide instructions for the correct and safe use of this product. Keep the user manual for future reference as it is an integral part of the product. The user manual shall be stored at an easily accessible location.
  • Page 3: Table Of Contents

    TED Pack Single, FR output Table of contents Introduction ................................4 Before Using the Product ..........................4 Intended Use ............................... 4 Text Conventions ..............................4 Acronyms and Abbreviations .......................... 4 Symbols and Signal Words ..........................5 Symbols on the Information Label ........................5 Safety ..................................
  • Page 4 TED Pack Single, FR output DMX Fail ..............................25 Dimmer Speed ............................25 Display OFF ..............................25 Display Invert ............................25 Factory Reset ............................25 DMX Channels ..............................26 RDM Information ...............................27 RDM Details ..............................27 Supported RDM PIDs for the Device .......................27 Troubleshooting ..............................28 Maintenance ..............................28 Safety Instructions for Maintenance ......................28 Preventive Maintenance ..........................29 Basic Cleaning Instructions ........................29...
  • Page 5: Introduction

    After unpacking, check the contents of the box. If any parts are missing or damaged, contact your Highlite International dealer. Your shipment includes: ● Showtec TED Pack Single, FR output ● Schuko to Seetronic power cable (1,5 m) ● User manual Fig.
  • Page 6: Symbols And Signal Words

    TED Pack Single, FR output Symbols and Signal Words Safety notes and warnings are indicated throughout the user manual by safety signs. Always follow the instructions provided in this user manual. Indicates an imminently hazardous situation which, if not avoided, will result in DANGER death or serious injury.
  • Page 7: Safety

    TED Pack Single, FR output Safety Important Read and follow the instructions in this user manual before installing, operating or servicing this product. The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual. Warnings and Safety Instructions DANGER Danger for children...
  • Page 8 TED Pack Single, FR output Attention Power supply ● Before connecting the device to the power supply, make sure that the current, voltage and frequency match the input voltage, current and frequency specified on the information label on the device. ●...
  • Page 9: Requirements For The User

    TED Pack Single, FR output Attention Do not expose the device to conditions that exceed the rated IP class conditions. This device is IP20 rated. IP (Ingress Protection) 20 class provides protection against solid objects greater than 12 mm, such as fingers, and no protection against harmful ingress of water. Requirements for the User This product may be used by ordinary persons.
  • Page 10: Description Of The Device

    TED Pack Single, FR output Description of the Device The TED Pack Single, FR output is a trailing-edge one-channel dimmer with a built-in control fader for indoor use. It can be operated in dimmer, switch and FX modes. The device is compatible with LED and incandescent lights.
  • Page 11: Top View

    TED Pack Single, FR output Top View Mounting hole for clamp 2 x Safety eyes Fig. 04 Dimensions Fig. 05 Fig. 06 Product code: 50444FR...
  • Page 12: Product Specifications

    TED Pack Single, FR output Product Specifications Model: TED Pack Single, FR output Electrical: Input voltage: 220–240 V AC, 50 Hz Power consumption: Fuse: F3 A, 250 V Output wattage (per channel): 500 W max Output current (per channel): Physical: Dimensions: 221 x 105 x 80 mm (L x W x H) Weight:...
  • Page 13: Installation

    TED Pack Single, FR output Installation Safety Instructions for Installation WARNING Incorrect installation can cause serious injuries and damage of property. If trussing systems are used, installation must be carried out only by instructed or skilled persons. Follow all applicable European, national and local safety regulations concerning rigging and trussing. Personal Protective Equipment During installation and rigging wear personal protective equipment in compliance with the national and site-specific regulations.
  • Page 14: Connecting To Power Supply

    TED Pack Single, FR output Fig. 07 Connecting to Power Supply DANGER Electric shock caused by short-circuit The device accepts AC mains power at 220–240 V and 50 Hz. Do not supply power at any other voltage or frequency to the device. This device falls under IEC protection class I.
  • Page 15: Setup

    TED Pack Single, FR output Setup Warnings and Precautions Attention Connect all data cables before supplying power. Disconnect power supply before connecting or disconnecting data cables. DMX Connection DMX-512 Protocol The TED Pack Single, FR output has 3-pin DMX signal IN and OUT connectors. The pin assignment is as follows: pin 1 (ground), pin 2 (-), pin 3 (+).
  • Page 16: Dmx Linking

    TED Pack Single, FR output DMX Linking To connect multiple devices on one DMX data link, follow the steps below: Use a 3-pin DMX cable to connect the DMX OUT connector of the lighting controller to the DMX IN connector of the first device. The DMX LED indicator (A) on the control panel (03) lights up. Connect the first device’s DMX OUT connector to the second device’s DMX IN connector with a 3-pin DMX cable.
  • Page 17: Operation

    TED Pack Single, FR output Operation Safety Instructions for Operation Attention This device must be used only for the purposes it is designed for. This device is intended for professional use as a trailing-edge dimmer. It is suitable only for indoor installation.
  • Page 18: Leading-Edge Dimming

    TED Pack Single, FR output Leading-edge Dimming Leading-edge dimming is a forward-phase dimming with a phase-cut at the beginning of each wave’s half cycle after the zero crossing (see Fig. 12). The leading-edge dimmers were originally developed to dim incandescent and halogen lamps. As they have a high minimum load, they are not suitable for low wattage LED lamps.
  • Page 19: Operation Modes

    TED Pack Single, FR output Operation Modes The TED Pack Single, FR output can be operated in dimmer mode, switch mode, and FX mode. Dimmer Mode In dimmer mode the device functions as a dimmer and you can control the intensity of the light output of the connected fixture(s).
  • Page 20: Control Panel

    Use the ENTER button to open the selected submenu. Start-up At start-up the display shows a splash screen with the logo of Showtec followed by the start screen. The start screen provides information about the selected DMX personality and the configuration of the output: ●...
  • Page 21: Menu Overview

    TED Pack Single, FR output Menu Overview Product code: 50444FR...
  • Page 22 TED Pack Single, FR output Product code: 50444FR...
  • Page 23: Main Menu Options

    TED Pack Single, FR output Main Menu Options The main menu has the following options: DMX Address Curve DMX Person Manual Information DMX Fail Status Dimmer Speed Dimmer Mode Display OFF Min Output Display Invert Max Output Factory Reset DMX Merge Press the UP/DOWN buttons to navigate through the main menu.
  • Page 24: Information

    TED Pack Single, FR output Information In this menu you can view the device’s parameters: frequency, firmware version, date of installation of the firmware, and UID. Status In this menu you can view the dimming percentage selected in manual mode. See 6.7.10 Manual on page 24 for more information.
  • Page 25: Maximum Output

    TED Pack Single, FR output Maximum Output In this menu you can set the maximum light output of the connected fixture(s). Press the UP/DOWN buttons to set the maximum light output. The selection range is 49–100 %. Note: In switch mode and in FX mode you cannot set the maximum light output of the connected fixture(s). DMX Merge In this menu you can select the merging mode for the signals received from the DMX input, the control panel and the control fader.
  • Page 26: Dmx Fail

    TED Pack Single, FR output DMX Fail In this menu you can set the behavior of the device in case of a DMX failure. Press the UP/DOWN buttons to select one of the following 3 options: ● Manual: The device will use the values selected in manual mode. See 6.7.10. Manual on page 24 for more information ●...
  • Page 27: Dmx Channels

    TED Pack Single, FR output DMX Channels Dimmer Switch Function Value Setting 1 CH 1 CH 2 CH Dimmer 000–255 Output 1 adjustable (0–100 %) Switch 000–127 Output 1 disabled (set to 0 %) 128–255 Output 1 enabled (set to 100 %) Safety channel 000–120 Disable control over output 1 (output remains...
  • Page 28: Rdm Information

    This device supports RDM. Refer to 6.9.2. Supported RDM PIDs for the Device for more information. RDM Details ● Responder ID: 29B4:090XXXXX ● Manufacturer's ID: Showtec (Highlite International B.V.) ● Manufacturer Label: Showtec ● Model Description: TED Pack Single ●...
  • Page 29: Troubleshooting

    TED Pack Single, FR output Troubleshooting This troubleshooting guide contains solutions to problems which can be carried out by an ordinary person. The device does not contain user-serviceable parts. Unauthorized modifications to the device will render the warranty void. Such modifications may result in injuries and material damage.
  • Page 30: Preventive Maintenance

    TED Pack Single, FR output Preventive Maintenance Attention Before use, examine the device visually for any defects. Make sure that: ● All screws used for installing the device or parts of the device are tightly fastened and are not corroded. ●...
  • Page 31: Deinstallation, Transportation And Storage

    TED Pack Single, FR output Deinstallation, Transportation and Storage Instructions for Deinstallation WARNING Incorrect deinstallation can cause serious injuries and damage of property. ● Let the device cool down before dismounting. ● Disconnect power supply before deinstallation. ● Always observe the national and site-specific regulations during deinstallation and derigging of the device.
  • Page 32 ©2022 Showtec...

This manual is also suitable for:

50444fr

Table of Contents