Download Print this page
Vent-Axia Centrif Duo Installation And Wiring Instructions
Vent-Axia Centrif Duo Installation And Wiring Instructions

Vent-Axia Centrif Duo Installation And Wiring Instructions

Advertisement

Quick Links

Centrif Duo &
Centrif Duo Plus
Installation and Wiring Instructions
For surface mounted models
220-240V~50Hz
PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE
INSTRUCTIONS.
Centrif Duo Plus
Stock Ref. N°
Centrif Duo P 25 61 20E
Centrif Duo T 25 62 20E
Centrif Duo DP 25 63 20E
Centrif Duo HTP 25 64 20E
Centrif Duo Plus P 43 16 13C
Centrif Duo Plus T 43 16 14C
Centrif Duo Plus DP 43 16 15C
Centrif Duo Plus HTP 43 16 16C
Centrif Duo
IPX4

Advertisement

loading

Summary of Contents for Vent-Axia Centrif Duo

  • Page 1 Centrif Duo T 25 62 20E Centrif Duo DP 25 63 20E Centrif Duo HTP 25 64 20E Centrif Duo Plus P 43 16 13C Centrif Duo Plus T 43 16 14C Centrif Duo Plus DP 43 16 15C Centrif Duo Plus HTP 43 16 16C...
  • Page 2 Centrif Duo and Centrif Duo Plus Features ● ● ● ● Surface mountable only Washable filter (available separately for ● ● ● ● Centrif Duo Plus) ● ● ● Pullcord ● ● ● ● Trickle speed LS connection (to boost from a remote switch ●...
  • Page 3: Safety And Guidance Notes

    K. Children should be supervised to ensure that they do not play with the appliance. DESCRIPTION As standard, the Centrif Duo and Centrif Duo Plus are suitable for panel/wall installations, surface mounting, either in a horizontal or vertical plane. Ø100mm ducting (flexible or rigid) can be attached providing rear exit as standard.
  • Page 4 Cut a 105mm hole, then suitable screw holes in the panel, ensuring that there is sufficient space for the product to be installed and that the filter (sold separately for the Centrif Duo Plus) can be removed for maintenance. Either the cardboard fitment or the fan chassis can be used as a template.
  • Page 5 B. SETUP WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING INSTALLATION OR MAINTENANCE. TO ACCESS THE SPEED CONTROLS/PCB, REMOVE THE 2 SCREWS HOLDING THE PCB COVER IN PLACE (SEE FIG 3). 1. SELECTING THE CONSTANT TRICKLE (with Boost) OPTION All models have the ability to have a constant trickle speed with an option to boost if required.
  • Page 6: Servicing And Maintenance

    To REDUCE the operating time, turn the timer adjuster ANTI-CLOCKWISE. To INCREASE the operating time, turn the timer adjuster CLOCKWISE. 4. RELATIVE HUMIDITY ADJUSTMENT (HTP model only) NOTE:- On installation it is possible that the humidity controller will run continuously until it has acclimatized to the environment.
  • Page 7 Fig.1. Backdraught shutter assembly. Spigot. Fig.2. Centrif Duo Plus Centrif Duo Cover Assembly. Cover Screws.
  • Page 8 Centrif Duo Plus shown Fig.3. Cover screws Terminal Block Cover. Terminal block Chassis Assembly. Impeller. Fig.4. Cable entry hole position Cable Clamp. Grommet Terminal Block Cover Humidity Adjustment (HTP models only). Turn clockwise to raise set point (decrease sensitivity). Timer Adjustment (T and HTP models only).
  • Page 9 Fig 7. Setup WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING INSTALLATION OR MAINTENANCE. TO ACCESS THE SPEED CONTROLS/PCB, REMOVE THE TWO SCREWS HOLDING THE PCB COVER IN PLACE.
  • Page 10 Fig 8. Siting of the fan.   Fig 9. Wiring diagram without LS connection. 1 Phase Supply (220-240V 50 Hz) 3A Fuse 2 Pole Isolator Switch Pull Cord (if applicable) Fig 10. Wiring diagram with LS connection. 1 Phase Supply (220-240V 50 Hz) Ceiling Junction Fuse...
  • Page 12 Vent-Axia guarantees its products for two years from date of purchase against faulty material or workmanship. In the event of any part being found to be defective, the product will be repaired, or at the Company’s option replaced, without charge, provided that the product:- ...