i.
To REDUCE the operating time, turn the timer adjuster ANTI-CLOCKWISE.
ii.
To INCREASE the operating time, turn the timer adjuster CLOCKWISE.
4. RELATIVE HUMIDITY ADJUSTMENT (HTP model only)
NOTE:- On installation it is possible that the humidity controller will run continuously until
it has acclimatized to the environment.
The fan's relative humidity (RH) set-point is factory set to switch the fan on at about
75%RH. This set point can be raised or lowered by altering the upper adjuster of the two
on the PCB (fig.4 & 7).
i.
To LOWER the set-point, turn the humidity adjuster (fig.4 & 7 ) ANTI-CLOCKWISE. This
makes the fan more sensitive to RH, i.e. the fan will come on at a lower RH.
ii.
To RAISE the set-point, turn the humidity adjuster (fig.4 & 7) CLOCKWISE. This makes
the fan less sensitive to RH, i.e. the fan will come on at a higher RH.
The fan will continue to run at boost after the RH has dropped below the set point for the
time period set by the timer adjustment (see 3. TIMER ADJUSTMENT, above)
C. WIRING.
WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE
ISOLATED FROM THE POWER SUPPLY DURING INSTALLATION OR
MAINTENANCE.
Use 0.75mm
1.
Select and follow the appropriate wiring diagram (fig. 9 or 10).
2.
Use the Cable Clamp and grommet provided (fig.4).
3.
Check all connections have been made correctly and ensure all terminal connections are
securely fastened.
D. SERVICING AND MAINTENANCE.
WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE
ISOLATED FROM THE POWER SUPPLY DURING SERVICING AND
MAINTENANCE.
1.
At intervals appropriate to the installation, the fan should be inspected and cleaned to ensure
there is no build up of dirt or other deposits.
2.
If fitted, remove the Filter and wash it and the front cover assembly in warm soapy water. Dry
them before replacing.
3.
Wipe the inlets and front face with a damp (not dripping wet) cloth until clean.
4.
Replace the filter.
5.
Turn the power to the fan back on.
The fan has sealed for life bearings, which do not require lubrication.