Basic Programming Mode - Pentair FLECK 2750 NXT Installer Manual

Table of Contents

Advertisement

6.2.4

Basic programming mode

6.2.4.1
Basic programming mode chart
Parameter
DAY OVERRIDE /
OFF to 99
TIME DRIVEN
4, 8, 12, 16,
REGENERATION
TIME
HARDNESS
1 to 1999
1 to 199.9
1 to 140.2
VOLUME
REMAINING
PUSH SETTINGS
6.2.4.2
Day Override / Time-driven
Set the maximum number of days between two regenerations, regardless from the volume of
water treated.
Mandatory
Must be set for timeclock valve !
Ref. MKT-IM-026 / C - 15.12.2020
Options
Definition
20
1 to 99
00:00 to
23:59
mg CaCO
hardness unit is mg/L
°FTH if hardness unit is
1 to 112
°dH if hardness unit is
°eH if hardness unit is
ON
(default)
OFF
Installer manual Fleck 2750 NXT/NXT2 - Programming
Day
This screen will not be displayed if day
of week regeneration has been
selected.
Days between regenerations only for
metered regeneration types.
Hour
This screen will not be displayed if day
of week regeneration has been
selected.
Day
Hours or days between regenerations
only for time clock regeneration type.
Hour
Regeneration time will not appear
when day override/time driver is by
hours for time clock or OFF for meter
immediate regeneration type, unless
remote delayed regeneration has
been activated.
/L equivalent if
Those screens will only display when
3
regeneration type selected is softener
meter immediate or delayed.
Even if maximum theoretical
°FTH
programmable value is 9999 or 999.9
(depending on the unit), the controller
°dH
will consider only up the value listed
in the side column.
°eH
Litre
Only displayed for multi units
systems.
-
Note
89 / 170