Function
Default setting
Duress/panic code
Disabled
Cross zone
Disabled
Table 9 below describes nonprogrammable (hard-coded) system
operation, as required to meet ANSI-SIA CP-01.
Table 9: Nonprogrammable system operation
Function
Silent exit
Remote arming exit time and
progress annunciation
Abort annunciation
Cancel report annunciation
Recent closing
Exit error
Restoration of power
Cancel alarm
Central station reporting
Note: The panel shall not be set or programmed to place a call to
a police station number that has not been specifically assigned by
that police station for such service.
Caution:
If call waiting is used on a non-call waiting line,
successful connection to the central station may be prevented.
The panel has been tested with the following central station
receivers using SIA and Contact ID reporting formats:
Before beginning installation, installers must verify that the central
station is equipped with the following receivers:
Radionics D6600 central station receiver
Sur-Gard central station receiver with models SG-DRL2A and
SG-CPM2
CS5000 digital alarm communicator receiver
UL Canada listed installations
This section describes the requirements for CUL (UL Canada) listed
installations.
Canadian standards CSA certified accessories:
Standard Class 2, 9 VAC, 30 VA power transformer (UTC Fire &
Security model 22-153-CN) or Standard Class 2, 9 VAC, 25 VA,
(UTC Fire & Security model 22-155-CN).
Simon XTi Installation Guide
Required setting
Disabled
Disabled for zones with
high probability of false
alarms
Operation
All annunciators enabled
All annunciators enabled
Enabled
Enabled
Enabled (2-minute window)
Enabled
Panel resumes operation in same
arming state and disregards alarm
signals from sensors for the first 60
seconds after power restoration
Enter code only
Residential burglary alarm system unit (ORD-C1023-1974): basic
system as described for UL 1023 listed installations plus:
Hardwired magnetic contact (1038T) or wireless learn mode
door/window sensor (60-670)
Siren timeout set to six minutes or more
Residential fire warning system control unit (ULC-S545-M89): basic
system as described for UL 985 listed installations plus:
Wireless smoke sensor 60-848-02-95, TX-6010-01-1 learned
into sensor group 26
Siren timeout set to six minutes or more
FCC compliance
This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of the FCC
rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a
residential environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful
interference to radio communications.
Changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to
operate the equipment.
FCC Part 15 registration number: B4Z-910C-SIMON
IC: 1175C-910CSIMO
This Class B digital apparatus complies with Canadian ICES-001.
Cet appareil numérique de la classe B est conforme à la norme
NMB-003 du Canada.
Part 68. This equipment complies with Part 68 of the FCC rules and
the requirements adopted by ACTA.
FCC registration number: US: B4ZAK02B55910
Canada: 1175C-910CSIXT
Ranger Equivalence 0.2B
Load Number 0.2