USER'S GUIDE
DR SERIES
CEILING FAN HEATER
WARNING
Before installing and operating this product, the user and/or installer must read, understand and follow these instructions and keep them handy for future
reference. If these instructions are not followed, the warranty will be considered null and void and the manufacturer deems no further responsibility for this
product.
This product must be installed by a qualified person and connected by a certified electrician, according to the electrical and building codes effective
in your region.
The following instructions must be adhered to in order to avoid personal injuries or property damages, serious injuries and potentially fatal electric shocks.
Protect the heating unit with the appropriate circuit breaker or fuse, in accordance with the nameplate.
Make sure the line voltage (volt) is consistent with that indicated on the unit's nameplate.
This unit must be grounded.
Switch off the power at the circuit breaker/fuse before installing, repairing and cleaning the unit.
Make sure the unit is appropriate for the intended use (if needed, refer to the product catalog or a representative).
RECOMMENDED HEATING CAPACITY :
1.25 W/cubic foot (0.03 m³).
It corresponds to 10 W/square foot (0.09 m²) based on a standard ceiling height of 8 feet (2.44 m). The recommended capacity is usually sufficient for
normal heating needs. Please note that the insulation quality of walls and windows are some of the factors that influence heat losses, which modify the
required capacity to heat a room. If needed, refer to a specialist (industrial and commercial buildings) who will be able to calculate these heat losses and
optimize the required capacity or consult the "Online heating calculation" section of the Stelpro Design Web site (residential buildings). To heat a large room
and to increase your comfort, it is recommended to install several units instead of one. For example, 2 X 1000 W rather than 1 X 2000 W.
For further information or to consult this guide online, please visit our website at www.stelpro.com
REPLACEMENT COMPONENT LIST INCLUDED
This unit
adesmarais
CRÉÉ PAR | CREATED BY :
2009-02-10
CRÉÉ LE | CREATED ON :
complies
2013-09-11 / adesmarais
MIS À JOUR | UPDATED :
with CSA
TOLÉRANCES SI NON-SPÉCIFIÉES | TOLERANCES IF NOT SPECIFIED
|
|
LINÉAIRE
LINEAR:
ANGULAIRE
ANGULAR:
L'INFORMATION CONTENU E DANS CE
standards
DOCUMENT E ST LA PROPRIÉTÉ DE
±.03"
[ ±.76mm ]
STELPRO DESIGN. EN AUCUN CAS,
.XX
=
XX°
=
L'INFORMATION NE PEUT ÊTRE
UTILISÉE, SAUF SOUS AUTORISATION
.XXX
=
±.015"
[ ±.38mm ]
XX.X°
=
ÉCRITE DE STELPRO DESIGN.
THE INFORMATION IN THI S DOCUMENT
IS THE PROPERTY OF STEL PRO DESIGN.
IN ANY CASE, THE INFORMATION CAN'T
BE USED, EXCEPT BY THE WRITTEN
EMPLACEMENT:
X:\01_PRODUITS\FAMILLES\DR\DOCUMENTATION\DR_COUVERTURE MANUEL.dft
CONSENT OF STELPRO DESIGN.
# PIÈCE | PART # :
DR-1, DR-R & DR-2
DESCRIPTION :
MATÉRIEL | MATERIAL :
±1°
B
FORMAT | SIZE :
TROISIÈME ANGLE DE
±0.5°
PROJECTION
1 / 1
FEUILLE | SHEET :
THIRD ANGLE PROJECTION
INSDR0317

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DRAGON DRR and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Stelpro DRAGON DRR

  • Page 1 If needed, refer to a specialist (industrial and commercial buildings) who will be able to calculate these heat losses and optimize the required capacity or consult the “Online heating calculation” section of the Stelpro Design Web site (residential buildings). To heat a large room and to increase your comfort, it is recommended to install several units instead of one.
  • Page 2: Specifications

    WARNING If the unit capacity is insufficient for the size of the room, it will be in operation continuously, and may become defective earlier and turn yellow. Respect distances and positions indicated in the installation section If the installer or the user modifies the unit, he will be held responsible for any damage resulting from this modification, and the CSA certification could be void. This unit must not come into contact with a water source and must be protected from splashes.
  • Page 3: Installation

    TECHNICAL DRAWINGS DRII 6 9/16" 167mm FRONT 2 7/16" 3 3/16" 62mm 81mm 22 3/8" 568mm 1 7/16" 37mm 7/8" 22mm 22 3/8" 568mm BOTTOM 22 1/2" 571mm 1" 1 1/4" 25mm 32mm 4 3/16" 4 15/16" 106mm 125mm 7/8" 22mm 23 5/8"...
  • Page 4: Maintenance

    ANGULAR: DOCUMENT E ST LA PROPRIÉTÉ DE LINÉAIRE LINEAR: ANGULAIRE ANGULAR: L'INFORMATION CONTENU E DANS CE STELPRO DESIGN. EN AUCUN CAS, ±.03" [ ±.76mm ] XX° ±1° DOCUMENT E ST LA PROPRIÉTÉ DE [ ±.76mm ] L'INFORMATION N E PEUT ÊTRE STELPRO DESIGN.
  • Page 5: Troubleshooting

    TROUBLESHOOTING PROBLEM DEFECTIVE PART OR PART TO CHECK • Defective thermostat or wrong thermostat setting • Open circuit breaker or fuse The unit does not work • The thermal protection has been activated • Faulty connections • Defective thermostat or wrong thermostat setting The unit runs continuously •...
  • Page 6: Limited Warranty

    Moreover, it does not cover the cost of disconnection, transport, and installation. The warranty is limited to the repair or the replacement of the unit or the refund of its purchase price, at the discretion of Stelpro. Any parts replaced or repaired within the warranty period with the written authorization of Stelpro will be warranted for the remainder of the original warranty period.