13.1
Description
General
Capacity
Empty Weight
Maximum floor load
Maximum operating pressure
- installation
Maximum operating pressure
- tank
Control thermostat -
adjustment range
Control thermostat -
default value
Hysteresis upwards -
adjustment range
Hysteresis upwards -
default value
Number of (electrical) anodes -
Minimum measured air
pressure differential across
the pressure switch
Setpoint pressure switch
Heating time ΔT = 45 °C
Electrical
Electrical power consumption
(peak)
Electrical power consumption
(nominal)
0312884_SCC_UKUK_V1.0, 2017-10-03

Appendices

Technical details

Unit
l
160
kg
95
kg
255
kPa (bar)
550 (5.5)
kPa (bar)
800 (8)
°C
40...85
°C
65
°C
2...15
°C
10
1
Pa
≥ 210
Pa
175
min.
28
(40-40)
18
(40-70)
W
85
W
25
(40-40)
36
(40-70)
200
245
106
120
306
365
550 (5.5)
550 (5.5)
800 (8)
800 (8)
40...85
40...85
65
65
2...15
2...15
10
10
1
2
≥ 210
≥ 460
175
400
43
26
(50-40)
(65-80)
28
20
(50-70)
(65-110)
85
105
25
51
(50-40)
(65-80)
36
85
(50-70)
(65-110)
285
380
136
155
421
535
550 (5.5)
550 (5.5)
800 (8)
800 (8)
40...85
40...85
65
65
2...15
2...15
10
10
2
2
≥ 460
≥ 460
400
400
33
32
(75-80)
25
(75-110)
105
105
51
85
(75-80)
85
(75-110)
81