Electrical Connections; Preparation - State Water Heaters SCC 40-40 Installation, User And Service Manual

Table of Contents

Advertisement

8.8
w
c
8.8.1
0312884_SCC_UKUK_V1.0, 2017-10-03
Description
Manufacture venting material
Construction
Material flue gas outlet
Material air inlet
Diameter flue gas outlet
Diameter air inlet
Refer to C13/C33 parallel systems (see section 8.7.2) for the STATE part numbers. The
same parts can be used for the C43, C53 and C63 parallel systems.
Use the "adapter box concentric to parallel - water heater side" (part number 0312209) for
C63 parallel systems.

Electrical connections

Warning
Leave the water heater electrically isolated until you are ready to commission it.
Caution
The water heater is phase-sensitive. It is absolutely essential to connect the mains live
(L) to the live of the water heater and the mains neutral (N) to the neutral of the water
heater.
Caution
There must be no potential difference between neutral (N) and earth (A). Use an isolating
transformer (see section 8.8.3.1) in the supply circuit when there is a potential difference.

Preparation

Remove the cover of the water heater to make the electrical section and the terminal block
visible:
1.
Use a hex driver to remove the screw (1) at the cover.
2.
Hold the cover at the sides.
3.
Lift the cover and take it from the water heater.
Fig. Remove the cover
Venting material
Venting material
PP
Alu
Muelink & Grol
Muelink & Grol
Parallel
Parallel
PP - Temp. Class T120 Thick walled aluminum
+0,6
80
/
mm
80
-0,6
+0,3
/
mm
-0,7
49

Advertisement

Table of Contents
loading

Table of Contents